Electrical Adjustments
Group/
Item Name
Item
13 Image AREA V HIGHT
14 Y - OFFSET TARTGET
15 CB OFFSET TARGET
16 CR OFFSET TARGET
17 Y-GAIN TARGET
18 CB-GAINTARGET
19 CR-GAINTARGET
20 OFFSET torelance
21 GAIN torelance
Group
CuStOM(Aspect)
270
0 Scaler Horizontal
1 Sclaler Vertical
2 Connect
3 Position Horizontal
4 Position Vertical
Group
AutoPC Adjust
280
0 AutoPCAdjustEnable
1 Frequency Step
2 Frequency Threshold
3 Fine Phase
4 BLKDET
5 PHASEMSK
Group
Paneltype * Panel type Check
290
0 GammaL/R-View
1 GammaL/R-Change
Group
Composite (NtSC) Composite / S-Video
500
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group
Composite (PAL) Composite / S-Video
501
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group
Composite (SeCAM) Composite / S-Video
502
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Group
SCArt(480i)
510
0
1 Disp Dots
2 H Back Porch
3 V Back Porch
4 Disp Line
Function
YCBCR Level Acquiring Area Height
Torelance of OFFSET Adj.
Torelance of GAIN Adj.
Horizontal Scaler Edit
Vertical Scaler Edit
Seperate/Connect Edit
Horizontal Postion Correction
Vertical Position Correct
Auto-PC Adj Operation Enable if Un-
supported Signal Input
Frequency Steps of Total Dot
Total Dot Freqency Threshold
Do Phase Adj after Total Dot Adj.
Black Level Detection Area
Phase Detection Filter
Current Setting Check
Setting of Gamma
-49-
Initial
range
9
0 - 4095
4
1 - 255
128
1 - 255
128
1 - 255
217
1 - 255
237
1 - 255
237
1 - 255
1
1 - 255
1
1 - 255
100
68-132
100
68-132
0
0-1
100
85-115
100
85-115
0
0-1
1
0-3
5
0-10
1
0-1
1
0 - 7
0
0 - 3
0
0-20
10
0-20
668
0 ~ 4095
28
0 ~ 4095
18
0 ~ 4095
458
0 ~ 4095
658
0 ~ 4095
34
0 ~ 4095
22
0 ~ 4095
536
0 ~ 4095
652
0 ~ 4095
28
0 ~ 4095
22
0 ~ 4095
536
0 ~ 4095
674
0 ~ 4095
132
0 ~ 4095
43
0 ~ 4095
452
0 ~ 4095
Note
0:Seperate, 1: Connect
0:Enabel, 1:Disable
0[]<-- - --> 10[Not
matched]
0;Excutes Fine Phase; 1:
Not Excute
0: Effective All Bit,
1: Disable Lower 1 bit
2: Disable Lower 2 bit, 3:
Disable Lower 3 bit
0: Gamma for L-Turn
20: Gamma for R-Turn *
Read only
Sets L-Turn Gamma if
the Value is set to 0.
Sets R-Turn Gamma if
the Value is set to 20.

Advertisement

Table of Contents
loading

Table of Contents