Sanyo PLC-WK2500 Service Manual page 47

Hide thumbs Also See for PLC-WK2500:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
Temp A Warning Offset
15
(Temp)
16 Temp B Warning Offset
(Temp)
17 Temp C Warning Offset
(Temp)
Temp B-A Warning Offset
18
(Temp)
19 Temp C-A Warning Offset
(Temp)
20 Temp A Warning Offset (Time)
21 Temp B Warning Offset (Time)
22 Temp C Warning Offset (Time)
Temp B-A Warning Offset
23
(Time)
Temp C-A Warning Offset
24
(Time)
Group
Fan Control range Setting (temp./Voltage)
254
0 High Fan Control Min Temp
1 High Fan Control Max Temp
2 High Fan1 Min
3 High Fan1 Max
4 High Fan2 Min
5 High Fan2 Max
6 High Fan3 Min
7 High Fan3 Max
10 Normal Fan Control Min Temp
Normal Fan Control Max
11
Temp.
12 Normal Fan1 Min
13 Normal Fan1 Max
14 Normal Fan2 Min
15 Normal Fan2 Max
16 Normal Fan3 Min
17 Normal Fan3 Max
20 Eco Fan Control Min Temp
21 Eco Fan Control Max Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
Group
Fan Start/Cooling Setting
255
0 Fan1 Initial Volt
1 Fan2 Initial Volt
2 Fan3 Initial Volt
4 Fan1 Cooling Speed
5 Fan2 Cooling Speed
6 Fan3 Cooling Speed
8 Cooling Time L1
9 Cooling Time L2
10 Temp Error Cooling Time
OnStart Cooling Start Thresh-
11
old
12 After shutdown cooling
Group
Fan/Lamp Voltage dimmer Setting
256
2 Fan 1 Speed Gain
3 Fan 2 Speed Gain
4 Fan 3 Speed Gain
Function
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X
minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
Temp Sensor Control Start/End Temp.
at Normal
Fan voltage value at Normal (unit:
0.1V)
Temp Sensor Control Start/End Temp.
at Eco
Fan voltage value at Eco (unit: 0.1V)
Fan Start Voltage(0.1V)
Fan Voltage at Power Off (0.1V)
Cooling Time setting at Fan Mode L1
(x 30 sec) 1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Fan Mode L2
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Temp Erro (x
30 sec)
Cooling after shutdown (0: No, 1: Yes)
Initial
5
5
5
0
0
3
3
3
3
3
Normal Ceiling HiLand-Normal
33
35
33/34
40
46
40/42
68
68
83/93
135
135
135
75
85
88/100
100
105
113/125
80
85
85/100
135
135
135
33
35
33/34
40
45
40/41
58
58
80/90
135
135
135
73
85
88/100
96
101
112/124
75
80
85/100
135
135
135
34
35
32/33
40
41
40
50
50
60/70
120
120
125
45
45
48/60
65
70
68/80
55
60
60/75
110
110
115
55
55
55
135
100
135
2
3
3
38
1
10
10
10
-47-
range
0-100
0-100
0-100
0-100
0-100
0-5
0-5
0-5
0-5
0-5
HiLand-Ceiling
35/36
-
On1/On2
43/44
-
On1/On2
85/95
-
On1/On2
135
-
98/110
-
On1/On2
118/130
-
On1/On2
90/105
-
On1/On2
135
-
35
20-100
On1/On2
42/43
20-100
On1/On2
85/95
0-255
On1/On2
135
0-255
101/113
0-255
On1/On2
117/129
0-255
On1/On2
90/105
0-255
On1/On2
135
0-255
34
20-100
On1/On2
41/42
20-100
On1/On2
65/75
0-255
On1/On2
125
0-255
48/60
0-255
On1/On2
73/85
0-255
On1/On2
65/80
0-255
On1/On2
115
0-255
0-255
0-255
0-255
0-255
0-255
0-255
1-15
1-15
1-15
0-100
0-1
0-255
0-255
0-255
Note