: Do not handle pressurized hoses. Escaping oil under pressure can penetrate the skin, causing serious
injury. If oil is injected under the skin, see a doctor immediately.
: Only use hydraulic cylinders in a coupled system. Never use a cylinder with unconnected couplers. If the
cylinder becomes severely overloaded, components can fail catastrophically causing severe personal injury or death.
3.0 TECHNICAL SPECIFICATIONS
The pump's maximum working pressure is 10,000 PSI (700kg/cm
rams, hoses, etc. used with this pump are rated at 10,000 PSI (700kg/cm
Remove SHIPPING PLUG (A) and install VENT PLUG (B) into cover plate.
Remove OIL FILLER CAP (C) and add SIMPLEX Hydraulic Oil into
reservoir. Oil level should not exceed 1" from the reservoir cover.
*
As a "rule of thumb" oil should be visual in site window when the unit
is powered down and all connected tools or cylinders are retracted.
••• 3 •••
2
). Make sure that all hydraulic equipment such as
2
) operating pressure.
www.tksimplex.com
Need help?