WFR 2460 Service Tips
WFR 2460 Service Tips
The water level (pressure switch) system consists of a mechanical
pressure switch and an analog pressure switch.
Mechanical Pressure Switch
The mechanical pressure switch (orange) has (3) switching
positions:
Water level < level 1
Water heating level
Overflow level
Analog Pressure Switch
The analog pressure switch (black) determines the different water
levels in the various wash programs. It is piezo-electric (pressure on
it generates a voltage) and generates between 0.5 - 3.5 VDC.
Its not helpful to measure the analog pressure
HINT:
switch voltage because its shown on the digital
display while the washer is in the test program.
Analog Pressure Switches
Analog Pressure Switches
--
Mechanical &
--
Mechanical &
Mechanical
Pressure
Switch
1st Edition/Revision 5 (1/20/04)
Analog
Pressure
Switch