Flexible Connector Hookup; Convert To Lp Gas; Burner Orifice Sizes And Output Ratings - Samsung NX58H9500W SERIES Installation Manual

Hide thumbs Also See for NX58H9500W SERIES:
Table of Contents

Advertisement

Available languages

Available languages

Flexible connector hookup

Installer: Inform the consumer of the location of the gas shut-off valve.
If your area requires a rigid pipe
hookup, contact a qualified
installer, service agency, or gas
supplier.
The gas shut-off valve should
be installed in an accessible
location in the gas piping,
external to the appliance, for the
purpose of turning on or shutting
off the gas to the appliance.
Step 3. Convert to lp gas (optional)
All new gas ranges are shipped from the factory set up to use natural gas. Any
Samsung gas range can be converted to use LP gas. Refer to page 72 in the
User Manual to contact a qualified service technician.
The conversion process should only be performed by a qualified LP gas installer.
Conversion instructions and LP orifices will be supplied with the LP conversion
kit. The conversion to LP requires all burner orifices to be changed (5 surface
burners and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All
replaced orifices must be left with the consumer, including the instructions and
retrofit sizes and orifice indication.
BURNER ORIFICE SIZES AND
OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner
BTU Rate
Location
RF
14,500
LF
11,500
RR
4,000
LR
7,500
CTR
7,500
BAKE
15,000
BROIL
11,500
¹Model NX58H9950W*
Gas Shut-Off Valve
Adapter
BURNER ORIFICE SIZES AND
OUTPUT RATINGS
(Natural Gas 5 in WCP)
Orifice Size
Burner
[mm]
location
In: 0.46/
Out: 0.74
RF¹
(2pcs)
1.04
RF²
0.62
LF
0.83
RR
0.83
LR
1.15
CTR
1.02
BAKE
BROIL
²Model NX58H9500W*, NX58K9500W*
English - 29
0.5-in or 0.75-in Gas Pipe
Tubing Line to
Oven Burner
Control Valve
Adapter
Tubing Line
to Cooktop
Control
Flex Connector
Manifold
(6-ft max.)
Pressure
Regulator
Orifice size
BTU Rate
[mm]
In: 0.70/
19,000
Out: 1.30
(2pcs)
In: 0.70/
18,000
Out: 1.30
(2pcs)
15,000
5,000
9,500
9,500
18,000
16,500
1.78
1.01
1.40
1.38
1.90
1.80

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx58h9950w seriesNx58k9500w series