NAME OF EACH PART
I Remote Control
G Remote Control Signal.
• Make sure it is not obstructed.
• Maximum distance : 10 m.
• Signal received sound.
One short beep or one long beep.
G Notes for Remote Control.
• Do not throw or drop.
• Do not get it wet.
• Certain type of fluorescent lamps may affect
signal reception. Consult your dealer.
G Do not place the remote control in a location exposed
to direct sunlight, or next to a heating unit, or other
heat source.
PREPARATION BEFORE OPERATION
I Indoor Unit
1
Connect the power supply cord to an independent
power supply.
HOW TO OPERATE
I To start the operation
• Press 1.
• POWER indicator (green) on the indoor unit will light up.
• To stop, press once more.
I Setting Mode
• Press 2 to select:-
Cooling Model
AUTO
– Automatic Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
FAN
– Air Circulation Operation
Heat Pump Model
AUTO
– Automatic Operation
HEAT
– Heating Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
1 Signal Transmitter
2 Operation Display
Cooling Model
H
H
Heat Pump Model
3 Room Temperature Setting Button
(Illuminating button)
4 Operation Mode Selection Button
5 Sleep Mode Operation Button
(Illuminating button)
6 Timer Setting Button
7 Timer Selection Button
8 OFF/ON Button
(Illuminating button)
9 Fan Speed Selection Button
0 Auto Airflow Direction Button
! Timer Set/Cancel Button
@ Manual Airflow Direction Selection Button
# Reset Point
(Press with fine-tipped object to clear the memory)
I Setting Temperature
• Press 3 to increase or decrease the temperature.
• The temperature can be set between 16°C ~ 30°C
• Recommended temperature:
1
Cooling Model
COOL –> 26°C ~ 28°C
DRY
–> 1°C ~ 2°C
lower than the
room temperature
• During AUTO Operation, press 3 to select:-
• Operation with 2°C higher than the standard
temperature.
• Operation with the standard temperature.
• Operation with 2°C lower than the standard
temperature.
G Standard Temperature
Indoor
temperature
23°C
• Once the Automatic Operation is selected, the indoor
temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.
• After the operation mode has been selected, the
mode does not change.
Indoor
temperature
23°C
20°C
• At the beginning of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected according
to the indoor temperature.
• After the operation mode has been selected, the
mode does not change.
G How to Insert the Batteries
1
2
G About the batteries
G Observe the following when replacing the batteries
G Proper way to operate the remote control in the
G Operation Details
COOL – Cooling Operation
Heat Pump Model
AUTO – Automatic Operation
COOL –> 26°C ~ 28°C
DRY
–> 1°C ~ 2°C
lower than the
room temperature
HEAT –> 20°C ~ 24°C
DRY – Soft Dry Operation
HEAT – Heating Operation
(for Heat Pump Model only)
Cooling Model
Standard
Operation
temperature
Cooling
25°C
Soft Dry
22°C
FAN – Air Circulation Operation
(for Cooling Model only)
Heat Pump Model
Standard
Operation
temperature
Cooling
25°C
Soft Dry
22°C
Heating
21°C
36
Gently press the place marked OPEN and slide
the cover towards you.
Insert the batteries
– Be sure the direction is correct.
• Can be used for approximately one year.
• Replace with new batteries of the same type.
• Do not use rechargeable batteries (Ni-Cd).
• Remove the batteries if the unit is not going to be
used for a long period.
case of ceiling/wall mounting.
• Operate the remote control in parallel with the floor.
(See the figure below)
(Fig. 1) Horizontal Level
O.K.
• The signal changes as shown in the figure below.
It means that the receiving conditions are bad and
the signal can not be controlled properly.
OUT
(Fig. 2)
To set the room temperature at your preference
cooling comfort.
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low Fan Speed.
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
Heated air rises and collects at the top of the room.
The air circulation circulates the heated air downward,
thus increasing heating effectiveness. When the unit
is installed floor mounted, you should set the
temperature higher than that of ceiling mounted.
At ceiling mounted
At floor mounted