Plug the NetScaler equipment into an outlet on a different circuit from your equipment. (Make sure the NetScaler equipment and your equipment are on circuits controlled by different circuit breakers or fuses.) Modifications to this product not authorized by Citrix Systems, Inc., could void the FCC approval and negate your authority to operate the product.
• One MPX Quick Start Guide • One Citrix NetScaler Resource CD • One power cable for the 7000, MPX 5500, and MPX 7500/9500 appliances • Two power cables for the 9010, 10010, 12000, MPX 15000, MPX 17000, MPX 9700/10500/12500/15500, and MPX 17500/19500/21500 appliances Note: Ensure that a power outlet is available for each cable.
Quick Installation and Configuration The following figure shows the front panel of the MPX 7500/9500 (4xSFP+4xCu) appliances. Figure 1-2. Citrix NetScaler MPX 7500/9500 (4xSFP+4xCu), front panel The following figure shows the back panel of the MPX 7500/9500. Figure 1-3. Citrix NetScaler MPX 7500/9500, back panel Configuration requirements Determine the following information for performing the initial configuration.
® ® Citrix NetScaler 9.3 Quick Start Guide: MPX 7500/9500 Platform is attached to the rack. The following figure illustrates the steps involved in mounting the Citrix NetScaler appliance to a rack. Figure 1-4. Rack mounting the appliance Appliance precautions w Determine the placement of each component in the rack before you install the rail.
Note: This section does not apply to the MPX 5500 appliance. The MPX appliances support both copper and fiber transceivers. Warning: Only those transceivers provided by Citrix Systems, Inc. are supported. Customers must not attempt to install third-party transceivers. Doing so voids the warranty.
All models function properly with a single power supply. The extra power supply on some models serves as a backup. The Citrix logo and LCD on the front of the NetScaler illuminate after the appliance starts, and the LCD indicates the operational status of the appliance.
Quick Installation and Configuration appliance. As long as the power cord is plugged in, line voltages are present in the power supply even when the power switch is off. w Do not use mats designed to decrease static electrical discharge as protection from electrical shock.
255.255.255.0 add ns ip 10.102.29.61 255.255.255.0 -type snip add route 0.0.0.0 0.0.0.0 10.102.29.1 set system user nsroot administrator save ns config reboot Note: For information about deploying a high availability (HA) pair, see the Citrix NetScaler Networking Guide at http://support.citrix.com/article/CTX128671.
Citrix NetScaler Hardware Installation and Setup Guide at http://support.citrix.com/ article/CTX128680. Note: For information about deploying a high availability (HA) pair, see the Citrix NetScaler Networking Guide at http://support.citrix.com/article/CTX128671. System Specifications The following table summarizes the specifications of the NetScaler MPX 7500/MPX 9500 appliances.
3. To view a short description of each document, hover your cursor over the title. To open a document, click the title. If you have support questions, please contact Citrix Technical Support at 1-800-4-CITRIX (1-800-424-8749). For additional contact information, see Support Phone Numbers at http://support.citrix.com/.