Hide thumbs Also See for FCQH71D8VEB:

Advertisement

technical data

Cooling Only/Heat Pump
FCQH-D8VEB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FCQH71D8VEB and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin FCQH71D8VEB

  • Page 1: Technical Data

    technical data Cooling Only/Heat Pump FCQH-D8VEB...
  • Page 2 technical data Cooling Only/Heat Pump FCQH-D8VEB...
  • Page 3: Table Of Contents

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB TABLE OF CONTENTS FCQH-D8VEB Features ............. 2 Specifications .
  • Page 4: Features

    High COP round flow cassette: up to class A energy labels • For auto cleaning panel: (Preliminary) - Daikin introduces first auto cleaning cassette to European market - Higher efficiency and comfort from daily auto cleaning of the filter • 360° air discharge ensures uniform air flow and temperature distribution - Lower maintenance costs thanks to auto cleaning function •...
  • Page 5: Specifications

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Specifications 2-1 Technical Specifications FCQH71D8VEB FCQH100D8VEB FCQH125D8VEB FCQH140D8VEB Casing Material Galvanised steel plate Dimensions Packing Height Width Depth Unit Height Width Depth Weight Unit Packed Unit Heat Exchanger Dimensions Length inside: 2,096, outside: 2,152...
  • Page 6: Electrical Specifications

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Specifications 2-1 Technical Specifications FCQH71D8VEB FCQH100D8VEB FCQH125D8VEB FCQH140D8VEB Safety devices Item Installation and operation manual Drain hose Clamp for drain hose Washer for hanger bracket Screws Installation guide Insulation for fitting...
  • Page 7: Options

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Options 3TW23259-1 B FCQH71-140 Max fresh air intake volume table The maximum intake air flow volume is following table. If the intake air flow volume is too large, the operating sound may rise or detection of the indoor unit suction temperature may be affected.
  • Page 8: Dimensional Drawing & Centre Of Gravity

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing with standard panel FCQH71D8 860 - 910 (Ceiling opening) See note 4 300 or less 710 (Suspension position) See note 3 Piping side Name Description...
  • Page 9: Dimensional Drawing With Auto Cleaning Panel

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Dimensional drawing & centre of gravity 5 - 2 Dimensional drawing with auto cleaning panel FCQH71D8VEB 860~910 (Ceiling opening) Name Description See note 3 710 (Suspension position) Liquid pipe connection Ø9.5 fl are connection...
  • Page 10: Dimensional Drawing With Accessoires

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Dimensional drawing & centre of gravity 5 - 3 Dimensional drawing with accessoires FCQH71D8 Service acces panel: Ventilation resistance in chamber (note 6) 450 x 450 mm or more (Refer to note 1) Name Description Indoor unit...
  • Page 11: Dimensional Drawing

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Dimensional drawing & centre of gravity 5 - 4 Dimensional Drawing FCQH71-140D8 Remote control dimensions Receiver installation procedure Transmitting part Receiver Pipe connection side Drain connection side Decoration panel Remote controller holder installation procedure (installation to wall surface) Receiver detail Liquid crystal...
  • Page 12: Centre Of Gravity

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Dimensional drawing & centre of gravity 5 - 5 Centre of gravity FCQH71-140D8 Models FCQH71 FCQH100~140 4TW28839-2 • Split Sky Air • Indoor Units...
  • Page 13: Piping Diagram

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Piping diagram FCQH71-140D8 Model Liquid Heat exchanger FCQH71 FCQH100 Ø15.90 Ø9.52 FCQH125 FCQH140 Liquid pipe connection port Gas pipe connection port Cooling Heating 3TW28925-1A • Split Sky Air • Indoor Units...
  • Page 14: Wiring Diagram

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Wiring diagram 7 - 1 Wiring diagram FCQH71-140D8VEB In case of simultaneous operation system 35~140-Class Indoor unit Indoor unit Indoor unit (master) (slave) (slave) To outdoor unit Receiver display unit Norm. emg. Central remote control (note1) Remote control...
  • Page 15: Sound Data

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Sound data 8 - 1 Sound pressure spectrum FCQH71D8 FCQH100D8 Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW31757-3 3TW31767-3 NOTES NOTES High-tap High-tap Low-tap Low-tap Data is valid at free field condition Data is valid at free field condition Data is valid at nominal operation condition Data is valid at nominal operation condition...
  • Page 16: Sound Power Spectrum

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Sound data 8 - 2 Sound power spectrum FCQH71D8 FCQH100~140D8 Octave band center frequency (Hz) Octave band center frequency (Hz) 3TW31757-1 3TW31767-1 NOTES NOTES High-tap High-tap dBA = A-weighted sound power level. (A-scale according to IEC) dBA = A-weighted sound power level.
  • Page 17: Air Flow Pattern

    • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Air flow pattern FCQH71D8 Cooling air velocity distribution All round air discharge, air flow direction: horizontal 2,7m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 2,7m 20°C 22°C...
  • Page 18 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Air flow pattern FCQH100D8 Cooling air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 3.2m 20°C 22°C...
  • Page 19 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Air flow pattern FCQH125D8 Cooling air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 3.2m 20°C 22°C...
  • Page 20 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Air flow pattern FCQH140D8 Cooling air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s Cooling air temperature distribution All round air discharge, air flow direction: horizontal 3.2m 20°C 22°C...
  • Page 21 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Air flow pattern FCQH71D8 Heating air velocity distribution All round air discharge, air flow direction: horizontal 2.7m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air temperature distribution All round air discharge, air flow direction: horizontal 2.7m 28°C 27°C...
  • Page 22 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Air flow pattern FCQH100D8 Heating air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air temperature distribution All round air discharge, air flow direction: horizontal 3.2m 28°C 27°C...
  • Page 23 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Air flow pattern FCQH125D8 Heating air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air temperature distribution All round air discharge, air flow direction: horizontal 3.2m 28°C 27°C...
  • Page 24 • Indoor Units • Cooling Only/Heat Pump • FCQH-D8VEB Air flow pattern FCQH140D8 Heating air velocity distribution All round air discharge, air flow direction: horizontal 3.2m 2.0m/s 1.5m/s 1.0m/s 0.5m/s 0.25m/s Heating air temperature distribution All round air discharge, air flow direction: horizontal 3.2m 28°C 27°C...
  • Page 25 Specifications are subject to change without environment. This challenge demands the eco design prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or and development of a wide range of products and an indirect damage, in the broadest sense, arising from or related to the use energy management system, resulting in energy and/or interpretation of this publication.