LG LTNS16121V /00 Service Manual page 38

Table of Contents

Advertisement

- Refrigerator Sensor Error
No
Checking
Check the voltage between white wires (these
4
are connected to PCB) for CON8.
Check the voltage between white wires
5
(sensor wires) for CON8.
Result and SVC countermeasure
Result
0
Short
OFF
Open
1. Check temperature and resistance
(see chart of section 7-2).
Other value
Normal
2. Go to step 5.
Result
0V
Out of
Replace (PCB)
Control
5V
1. Check temperature and resistance
Other value
(see chart of section 7-2).
Normal
between
2. Explain to customer about loose
0V & 5V
and dirty connectors.
38
SVC Support
Replace the product.
SVC Support