7-2 RESISTENCE, VOLTAGE & SPECIFIC TEMPERATURE FOR SENSORS
Sensors "RT" (Ambien Temperature)
Temperature
°C
-26.0
-24.0
-22.0
-20.0
-18.0
-16.0
-14.0
-12.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
22.0
24.0
26.0
28.0
30.0
32.0
34.0
36.0
REMARKS:
1. The sensor resistance has a variation of + 5%
2. Sensor resistance measurement must be done after 3 minutes since the sensor has been exposed to that temperature,
this is necessary for getting a reliable value.
3. For checking voltage, make sure of connection for PCB connector.
Resistence (k )
°F
-14.8
104.60
-11.2
94.30
-7.6
85.14
-4.0
76.96
-0.4
69.66
3.2
63.13
6.8
57.29
10.4
52.05
14.0
47.34
17.6
43.12
21.2
39.31
24.8
35.88
28.4
32.79
32.0
30.00
35.6
27.47
39.2
25.19
42.8
23.12
46.4
21.24
50.0
19.53
53.6
17.98
57.2
16.57
60.8
15.28
64.4
14.10
68.0
13.03
71.6
12.05
75.2
11.16
78.8
10.34
82.4
9.59
86.0
8.90
89.6
8.26
93.2
7.68
96.8
7.15
33
Voltage (V)*
4.56
4.52
4.47
4.43
4.37
4.32
4.26
4.19
4.13
4.06
3.99
3.91
3.83
3.75
3.67
3.58
3.49
3.40
3.31
3.21
3.12
3.02
2.93
2.83
2.73
2.64
2.54
2.45
2.35
2.26
2.17
2.08

Hide quick links: