Display Adjustment - Philips SH3L 170X4 Service Manual

15" tft lcd colour monitor
Table of Contents

Advertisement

Display Adjustment:

Menu
Auto
Press
and
button simultaneously while power ON.
Adjust OSD menu to lower position of screen (i.g. adjust OSD H-
Position and OSD V-Position to 0 at OSD setup sub-menu. Then
Down
Up
press
or
button to move the cursor to
item ( see table 1). Check CPU version if it is not right version,
then ISP new one (7310). After pre-check, aging 1 hour at least.
Programming Analog DDC data into Monitor. Check # serial
number to meet bar code label.
HUDSON 170X4 V200 2003-09-23
Table 2. The content of Factory setting.see table 2.
Cursor can move on gray color area
1. Auto color adjustment:
Apply a 48.36kHz/60Hz signal with white pattern. Set brightness
at 100% and contrast at 50%. Move the cursor by pressing
Down
AutoColor
button to
( see table 2 ), press OK button to do
auto color, scaler would calibrate offset1,offset2 and gain itself
then display OK. Check the 64-gray level is distinguishable.
2. Color temperature adjustment:
Apply a 48.36kHz / 60Hz signal with white pattern.Set brightness
control at 100% and contrast control at 50%. Adjust the R.G.B
gain to reach special color temperature on center of screen.
Keep one color fixed gain to maximum at least.
2.1 Aim the probe CA-30 at the center of screen as Fig. 1
2.2 Remove the lens protective cover of probe CA-30.
2.3 Set Measuring/viewing selector to Measuring position for reset
analyzer. (Zero calibration) as Fig. 2
2.4 Turn on the colour analyzer (CA-110).
2.5 Press 0-CAL button to start reset analyzer. See Fig.3
Display Adjustment
Factory Entrance
Table 1.
<------Factory mode indicator
<---Mean : it is running the
resolution now.
Table 2.
Up
or
Fig. 1
0-CAL
2.6 Switch light probe to Viewing position.
2.7 Move the Lens barrel forward or backward to get clear image as
shown in Fig. 4
2.8 Switch light probe to Measuring position. It should be able to
indicate colour value on the CA-110.
Measurement/viewing selector
Measurement/viewing selector
Menu
2.9 Press
buttons to select R G B of 9300 and 6500.
Increase / decrease value by press
1931 CIE chromaticity ( x, y ) as below.
9300° K
0.283 ± 0.020
x (center)
0.297 ± 0.020
y (center)
Alignment hits:
1. R for x value , G for y value, B for Y value on the colour analyzer.
2. Must to select 9300 in user mode, then 9300 is available in factory
mode.
3. Must to select 6500 in user mode, then 6500 is available in factory
Mode.
3. NVRAM(24C16) Default Values:
Sub_Bri:
0
255
Sub_Con: 98
128
158
VCOM:
160
4. Factory Reset:
After finishing all the adjustment, select Factory Reset function to
Recall:
To leave factory mode by restart the monitor.
5. EEPROM Presetting:
After finishing all the adjustment,Set:
Brightness control to 100%
Contrast control to 50%
OSD position at middle of screen.
Color Adjust to 6500K color.
When adjustment is finished,monitor should be set to 6500K.
170X4
Go to cover page
cover (black)
cover (black)
Measurement/viewing selector
Measurement/viewing selector
Fig. 2
Fig. 3
Clear image
Fig. 4
Up
Down
or
buttons until the
6500° K
sRGB
0.313 ± 0.020
0.313 ± 0.020
0.329 ± 0.020
0.329 ± 0.020
19

Advertisement

Table of Contents
loading

Table of Contents