Pace4/8/16PRM are long range Ethernet receivers that transmit data at 100mbps full duplex and power via CAT5e or higher
cable in a PoE(+) compliant format. The Pace4/8/16PRM receivers are powered via a PoE midspan such as the Altronix
Netway series or by an endspan. The receiver passes the PoE(+) compliant power over the cable to the Pace1PTM trans-
ceiver which in turn passes this power to an enabled IP camera/device. These plug and play units facilitate cost effective
solutions for IP devices that need to be installed at the distances greater than 100m. They also provide a simple way to
replace legacy analog products with new IP devices over structured cable.
Agency Listings:
• UL/CUL Listed for Information
Technology Equipment (UL 60950-1).
• CE approved.
• C-Tick compliant.
Input (Pace4/8/16PRM):
• Powered by midspan or endspan.
PoE compliant to IEEE 802.3af (15W) and
PoE+ compliant to IEEE 802.3at (30W).
Ethernet:
• Connectivity: RJ45, auto-crossover.
• Wire type: 4-pair CAT5 or 1 pair UTP structured cable.
• Distance: up to 450m.
• Speed: 100BaseT, full duplex, auto negotiation.
PoE compliant to IEEE 802.3af (15W) and PoE+
compliant to IEEE 802.3at (30W) delivered to
camera by Pace1PTM. Power provided by
Pace4/8/16PRM to Pace1PTM by PoE protocol.
CAT5e or Higher:
• Throughput is rated to pass 100mbps of data at
distances up to 450m. With proper headend
equipment, this supports Megapixel, HD720, HD1080.
• Distance: up to 450m @ 100mbps (see Maximum Length
of CAT5e Type vs. Camera Power/PoE Class, pg. 4).
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
Pace4/8/16PRM is not intended to be connected to outside plant leads and should be installed indoors within the protected
premises. The Pace4/8/16PRM and Pace1PTM are intended for indoor use only.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the
rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment
in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe
operation of the equipment is not compromised. Do not obstruct any air vents on the unit. It is recommended to leave half
space above and below the unit.
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due
to uneven mechanical loading.
Note: Caution: once PoE connection is established between Pace4/8/16PRM and Pace1PTM, disconnecting the CAT5
from Pace1PTM will not disable the PoE compliant voltage from the Pace4/8/16PRM, although the Pace1PTM can be
reconnected, caution should be taken not to connect the CAT5 wiring from Pace4/8/16PRM to any non-PoE device.
1. Pace4/8/16PRM installation:
a. Pace4PRM - Affix rubber pads to Pace4PRM for shelf installation (Fig. 5, pg. 6).
Pace8/16PRM - Attach mounting brackets to Pace8/16PRM unit for rack installation (Fig. 4, pg. 6).
Affix rubber pads to Pace8/16PRM for shelf installation (Fig. 5, pg. 6).
Unit should be located in proximity to ethernet switch/network, NVR or video server.
b. Connect structured cables from port marked [IN] on Pace4/8/16PRM to the corresponding inputs of an ethernet
midspan or endspan device (Fig. 3, pg. 4).
c. Connect structured cables from port marked [OUT] on Pace4/8/16PRM to Pace1PTM (Fig. 3, pg. 4).
- 2 -
Overview:
Features:
LED Indicators:
• Pace4/8/16PRM:
Green (RJ45) IP Link status, 100Base-T/active.
• Pace1PTM:
Yellow - PoE ON (by respective RJ45 jack).
Yellow & Green (RJ45) IP Link status, 100Base-T/active.
Environmental:
• Operating Temperature Pace4/8/16PRM/Pace1PTM:
-- 20ºC to +49ºC (-- 4ºF to 120.2ºF).
• Storage Temperature:
-- 30º to +70ºC (-- 22º to 158ºF).
• Humidity: 20 to 85%, non-condensing.
Applications:
• Works with Megapixel, HD720, HD1080 and VGA
(SD) cameras (see note, pg. 2).
• Extend Network link distance in an industrial
environment (see note, pg. 2).
Mechanical:
• Dimensions (H x W x D approx.):
Pace4PRM:
1.7" x 5.25" x 8.42" (43.8mm x 133.35mm x 213.9mm)
Pace8PRM/16PRM:
1.625" x 19.125" x 8.5" (42mm x 486mm x 216mm)
Pace1PTM:
1" x 2.5" x 4.375" (25.4mm x 63.5mm x 111.125mm)