SAFETY INSTRUCTIONS
SAFETY CHECK AFTER
SERVICING
Confirm
the specified insulation
resistance
between
power
cord plug prongs
and
externally
exposed
parts
of
the
set
is
greater
than
lOMohms,
but
for
equipment
with
external
antenna
terminals (tuner,
receiver, etc.)
and
is
intended
for
[Cl
or
[aI, specified insulation resistance
should be
more
than
2.2
Mohms
(ground
terminals,
microphone
jacks,
headphone
jacks,
line-in
-out
jacks
etc.)
PRECAUTIONS DURING SERVICING
1.
Parts identified
by
the
A
symbol
parts are
critical
for safety.
Replace only with
parts
number
specified.
2.
In
addition to
safety,
other
parts
and
assemblies
are specified for
conformance
with such
regulations
as
those
applying
to spurious
radiation.
These
must
also
be
replaced
only with
specified
replacements.
Examples:
RF
.converters,
tuner
units,
antenna
selector switches,
RF
cables, noise
blocking
capacitors, noise
blocking
filters,
etc.
3.
Use
specified internal wiring.
Note
especially
1)
Wires covered with
PVC
tubing
2)
Double
insulated wires
3)
High
voltage leads
4.
Use
specified insulating materials for
hazardous
live
parts.
Note
especially:
1
)
Insulation
Tape
2)
PVC
tubing
3)
Spacers
(Insulating Barriers)
4)
Insulation sheets
for transistors
5)
Plastic
screws
for fixing
microswitch
(especially
in
turntable)
5.
When
replacing
AC
primary
side
components
(transformers,
power
cords, noise
blocking
capacitors,
etc.),
wrap
ends of
wires securely
about
the terminals before soldering.
6.
Observe
that wires
do
not contact heat producing
parts (heatsinks,
oxide metal
film
resistors,
fusible
resistors, etc.).
7
.
Check
that
replaced wires
do
not contact
sharp
edged
or
pointed
parts.
8.
Also check
areas
surrounding
repaired locations.
9.
Use
care that foreign objects (screws, solder droplets,
etc.)
do
not remain
inside
the
set.
Voltage conversion
Models
for
Canada,
USA,
and Japan
are
not
equipped
with
this
facillity.
Each machine
is
preset
at
the factory
according
to
its
des-
tination,
but
some
machines can be
set
to
1
10V, 120V,
220V
or
240V
as required.
If
your machine's
voltage
can be
converted:
Before
conmnecting
the
power
cord, trun the
VOLTAGE
SELEC-
TOR
located
on
the
bottom
panel with a screwdriver
until
the cor-
rect
voltage
is
indicated.
2
SERVICE
MANUAL
AX80