M
N
L
Problem
No radio contact
Mist Generator not
functioning
(only for Ambiente 48 S)
Individual membrane /
membrane unit not
functioning
Mist effect falls off
In the event of other faults please contact GARDENA Service. Repairs should only
A
be carried out by GARDENA service centres or dealers authorised by GARDENA.
The following fuse is required :
• Ambiente 48 S (Art. 7977) :
Replacement fuses are available from GARDENA Service on
request.
L
1. Remove fuse cap
2. Unscrew fuse cover
N
3. Remove fuse
and insert a new one.
M
4. Screw fuse cover
L
5. Refit fuse cap
.
Probable Cause
Battery in remote control spent.
Antenna on remote control
not pulled out.
Antenna not fitted to generator.
Cable not inserted.
Defective cable / connection.
Water level too low.
Use of distilled water.
Fuse of transformer defective.
Membrane unit not fully
inserted in generator.
Membrane unit not correctly
inserted.
Membrane / membrane unit
defective.
Membranes soiled.
5 x 20, 250 V, 1,6 A, T
.
M
.
back on.
Remedy
v Replace battery.
v Pull out antenna on
remote control.
v Fit antenna to generator.
v Insert power plug.
v Remove power plug and
check all outgoing
connections and cables.
v Ensure water level is
sufficient.
v Do not use distilled water.
v Replace fuse.
v Fully insert membrane
unit in generator.
v Check / insert plug-in
connection to membrane
unit.
v Replace membrane /
membrane unit.
v Clean or replace
membranes.