Potterton mersey super Installation And Service Instructions Manual page 6

Non spouted multipoint model
Hide thumbs Also See for mersey super:
Table of Contents

Advertisement

Mersey Super - Installation & Service Instructions
Page 6 of 35
NOTE: Where the appliance is to be installed into a SEDUCT the minimum duct required is
228mm (9in) deep, 349mm (15½ in) wide.
Fig. 3
3. Where the building regulations require it, a flue terminal guard should be fitted
symmetrically around the outer part of the flue terminal.
4. Unpack the water heater. Find the bags of accessories before discarding the packaging.
5. Slide off the bottom cover then remove the three screws securing the outer case and
carefully lift it off.
Fig. 4
6. Use the self adhesive discs supplied to cover the unwanted fixing holes in the back of the
new appliance as shown.
Page 4
INSTALLATION - Page 5
7. Fit the flue terminal sealing strip (packed separately in the carton) into the recess around
the flue aperture in the back of the appliance.
file://P:\System\DATA\Dx\DS1\installation\2551\I24-2551\I24-2551.htm
09/12/2009