Fig. 11
Page 7
COMMISSIONING - Page 8
Fig. 12
NOTE: If a gas rate check is required, the gas consumption after 3 minutes running should
be approximately 48.5 l/mm (1.7³/min).
9. Turn OFF the hot water outlet and press the OFF button '
' on the appliance. Remove
the pressure gauge and replace the screw and sealing ring.
10. Relight the pilot. Turn ON a hot water outlet and check for gas soundness at the
pressure test point.
11. Turn OFF the hot water outlet. Slide the bottom cover onto the appliance.