PS1 Specifications
Continuous Power Rating
AC Voltage / Frequency Output
AC Input Current Maximum
Maximum AC Surge Current
Maximum PV Array Wattage
PV Open Circuit Voltage
MPPT Input Voltage Range
PV Array Ground Fault Protection
Inverter Efficiency
MPPT Efficiency
Overall System Efficiency
Battery Voltage - Nominal
Minimum / maximum operating range
Battery Charge Rate
AC Output Voltage Regulation
AC Output Current
Total Harmonic Distortion
AC Transfer Switch Speed
Battery Temperature Sensor
Operating Temperature Range
Recommended Minimum Energy Storage
Recommended Batteries
Communications
Enclosure Materials
Mounting
Recommended Mounting Hardware
System Enclosure Dimensions (H x W x D)
Battery Enclosure Dimensions (H x W x D)
System Weight
Battery Enclosure Weight (without batteries)
Certifications
Anti-Islanding Measures
Warranty
Field Installed Options
2005
Sealed Models
PS1-2500
At 40° C
2500 VA
At 25° C
3000 VA
120 VAC 60 Hz
AC Transfer Switch
50 amps AC
Battery Charger
16 amps AC with automatic back-off
Peak (1 millisecond)
70 amps AC
RMS (5 seconds)
50 amps AC
3300 watts DC stc rating
Maximum
150 VDC
44 to 135 VDC
Standard - 80 amp DC
Typical
91% (not CEC Certified)
Peak
93%
98%
Typical
89%
Peak
92%
48 VDC
40 to 60 VDC
Inverter
35 amps DC
MX60
60 amps DC
Typical
5%
Nominal
120 VAC
Inverting
25.0 amps AC
Selling
20.8 amps AC
Inverting
2% VAC THD
Selling
< 5% current THD per UL1741 conditions
Typical
< 16 Milliseconds
Included
-40° C to 60° C (power derated above 25° C)
4 kWHRS at 80% discharge
Four AGM type 31 or type 27 sealed VRLA
Optional MATE system display with RS232 port
Powder coated aluminum, stainless steel hardware
Wall mount, 16 on center studs
5/16 x 2.5" Lag Bolts - three per side minimum
Unit
31.3 x 17.25 x 12.9" (80 x 44 x 33 cm)
Shipping
40.5 x 20.5 x 17.25" (103 x 52 x 44 cm)
Unit
36.25 x 17.25 x 12.55" (92 x 44 x 32 cm)
Shipping
43.25 x 20.25 x 16.75" (110 x 51 x 43 cm)
Unit
107 lbs (49 kg)
Shipping
117 lbs (53 kg)
Unit
29 lbs (13 kg)
Shipping
47 lbs (21 kg)
ETL certified to the UL1741 standard
UL1741 compliant
5 year limited repair warranty standard
MATE or MATE2 remote system display
OBAC breakers for additional AC load circuits
OBPV breakers for PV array series string protection
Vented Models
PS1-3000
3000 VA
3600 VA
120 VAC 60 Hz
50 amps AC
20 amps AC with automatic back-off
70 amps AC
50 amps AC
3300 watts DC stc rating
150 VDC
44 to 135 VDC
Standard - 80 amp DC
91% (CEC Certified)
93%
98%
89%
92%
48 VDC
40 to 60 VDC
45 amps DC
60 amps DC
5%
120 VAC
30.0 amps AC
25.0 amps AC
2% VAC THD
< 5% current THD per UL1741 conditions
< 16 Milliseconds
Included
-40° C to 60° C (power derated above 25° C)
4 kWHRS at 80% discharge
Four AGM type 31 or type 27 sealed VRLA
Optional MATE system display with RS232 port
Powder coated aluminum, stainless steel hardware
Wall mount, 16" on center studs
5/16 x 2.5" Lag Bolts - three per side minimum
31.3 x 17.25 x 12.9" (80 x 44 x 33 cm)
40.5 x 20.5 x 17.25" (103 x 52 x 44 cm)
36.25 x 17.25 x 12.55" (92 x 44 x 32 cm)
43.25 x 20.25 x 16.75" (110 x 51 x 43 cm)
107 lbs (49 kg)
117 lbs (53 kg)
29 lbs (13 kg)
47 lbs (21 kg)
ETL certified to the UL1741 standard
UL1741 compliant
5 year limited repair warranty standard
MATE or MATE2 remote system display
OBAC breakers for additional AC load circuits
OBPV breakers for PV array series string protection
OutBack Power Systems Inc.
l
13
28

Advertisement

Table of Contents
loading

Table of Contents