  • Page 1 English Français Deutsch Italiano Español Nederlands Digital Ear Thermometer ® Model Gentle Temp Türkçe Instruction Manual IM-MC-521-E-01-03/2013 9063366-4A...
  • Page 2: Important Safety Information

    Important Safety Information To assure the correct use of the product basic safety measures should always be followed including the precautions listed below. Warning: • Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. •...
  • Page 3 Important Safety Information • Do not touch the infrared sensor with a finger or breathe on it. • Do not attempt measurements when the unit is wet as inaccurate readings may result. • Check the symbol on the display before and after the measurement so that the measurement is taken in the appropriate mode.
  • Page 4 1. Overview Main unit: Display: Infrared sensor Probe Probe cap Buzzer Probe cover detector Battery icon START button Memory icon Display Probe cover icon ON/MEM button Battery cover pick hole Ear temperature Surface temperature Battery compartment Room temperature Temperature mode Connection ring Probe cover...
  • Page 5: Removing The Insulating Tape

    2. Preparation Removing the Insulating Tape Pull the insulating tape out from the battery compartment by catching the outer part for the first time. The unit is turned on and after 1 minute the room temperature will appear on the display. Notes: •...
  • Page 6: Setting The Buzzer

    2. Preparation Setting the Buzzer The buzzer is only available in the Ear Measurement Mode. The buzzer is set on as default. Press the ON/MEM button to turn on the unit. Press and hold the ON/MEM button for 3 seconds. The “...
  • Page 7 2. Preparation Attaching a Probe Cover Always use a new and undamaged OMRON MC-EP2 probe cover. Gently twist off the probe cap. Note: Do not forcibly remove the probe cap. Place a new probe cover on the connection ring. Adhesive side Note: The adhesive side of probe cover should be upward.
  • Page 8: Using The Unit

    3. Using the Unit Taking a Reading Notes: • Make sure the probe cover is attached correctly. • It is recommended that you measure 3 times with the same ear. If the 3 measurements are different, select the highest temperature. Ear Measurement Mode Press the ON/MEM button.
  • Page 9 3. Using the Unit Measuring the temperature of an infant Measuring on Measuring on The ear is too small a lying baby. a sitting baby. to insert the probe. While slightly pulling Lightly support Lightly support the the ear back, cover the child’s body.
  • Page 10: Press The Start Button

    3. Using the Unit Press the START button. The measurement is complete in 1 second with a long beep. The display will light up and the “ ” symbol will flash for 5 seconds. Note: You can take another measurement after the display light turns off with 2 beeps. Make sure “...
  • Page 11 3. Using the Unit Surface Mode The unit is set in the Ear Measurement Mode as default. The Surface Measurement mode is not intended for the body temperature measurement. The surface mode shows the actual and unadjusted surface temperature which is different from the body temperature.
  • Page 12: Using The Memory Function

    3. Using the Unit Using the Memory Function This unit automatically stores the results up to 25 sets after each measurement. Note: If the memory is full, the unit will delete the oldest reading. Press the ON/MEM button to turn on the unit. Press the ON/MEM button again.
  • Page 13: Troubleshooting And Maintenance

    4. Troubleshooting and Maintenance The Icons and Error Messages Error Display Cause Remedy Device stabilization in process. Wait until stops flashing. Attach the probe cover again until stops Prove cover is not attached correctly. flashing. Replace the battery. Battery is low. (Refer to section 4.3) Measurement before device stabilization.
  • Page 14 Remove the battery, wait for 1 minute and repower it. If the message reappears, please contact the Error 5-9, the system is not functioning properly. OMRON retail outlet or distributor for having the device checked. Ear measurement mode: Check the integrity of the probe cover and take a Temperature taken is higher than 42.2°C...
  • Page 15 (Refer to section 4.3) Maintenance • Please check the device if damaged after it is dropped. If unsure, please contact the OMRON retail outlet or distributor for having the device checked. • The probe is the most delicate part of the unit. Use care when cleaning the Infrared sensor to avoid damage.
  • Page 16: Replacing The Battery

    4. Troubleshooting and Maintenance Replacing the Battery Battery: CR2032 Lithium Button Battery Note: To protect the environment, discard the used batteries in accordance with the local regulations regarding waste disposal procedure. Disposal can be done at your retail store or at appropriate collection sites. Insert a pointed object into the battery cover pick hole.
  • Page 17: Technical Data

    5. Technical Data Product Description: Digital Ear Thermometer Model: Gentle Temp 521 (MC-521-E) Sensing Unit: Thermopile Temperature Display: 4-digit, °F display in 0.1 degree increments 3-digit, °C display in 0.1 degree increments Measurement Accuracy: Ear Measurement Mode ± 0.2°C (± 0.4°F) within 35.5°C to 42.0°C (95.9°F to 107.6°F), ±...
  • Page 18 • The specification may be changed without prior notice. • This OMRON product is produced under the strict quality system of OMRON HEALTHCARE Co. Ltd., Japan. • This device fulfills the provisions of the EC directive 93/42/EEC (Medical Device Directive) and the European Standard...
  • Page 19 Recommendation is to keep a minimum distance of 7 m. Verify correct operation of the device in case the distance is shorter. Further documentation in accordance with EN60601-1-2:2007 is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual. Documentation is also available at www.omron-healthcare.com.
  • Page 20: Some Useful Information

    The Gentle Temp 521 Digital Ear Thermometer detects the infrared heat given off by the eardrum and surrounding tissues, and it converts this heat into an equivalent ear temperature. The Gentle Temp 521 is less threatening to a child than a rectal thermometer. It’s faster, safer and easier to use than an oral thermometer.
  • Page 21 6. Some Useful Information As ambient temperature, sweat, or saliva easily affects body temperature measured under the arm or the tongue, readings may be lower than the core temperature. Tympanic temperature measurement accurately reflects the brain temperature and can lead to a quicker detection of fever.
  • Page 22: Questions And Answers

    6. Some Useful Information Ear temperature compared to other types of body temperature The normal temperature varies according to different locations on the body. Questions and answers How many times can I measure consecutively? You can measure consecutively up to three times. The main unit will then be warmed up and may not be able to measure correctly.
  • Page 23 6. Some Useful Information Is the temperature measured in the right ear different from that measured in the left ear? Among healthy people, there should be no significant difference in the measurement results. Differences may be caused by the following reasons: 1) The infrared sensor is not inserted in the same way.
  • Page 24 <DQ .XUXOXú Gottlieb-Daimler-Strasse 10, 68165 Mannheim, GERMANY www.omron-medizintechnik.de OMRON SANTÉ FRANCE SAS 14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, FRANCE Uniquement pour le marché français: OMRON Service Après Vente Nº Vert 0 800 91 43 14 consommateurs@omron-sante.fr www.omron-sante.fr/contact Made in China Fabricado en China Fabriqué...

This manual is also suitable for:

Gentle temp 520