Connect Cables - Vivotek SD83X4E Quick Installation Manual

Hide thumbs Also See for SD83X4E:
Table of Contents

Advertisement

1. Disassemble the components of the waterproof connector into parts (A) ~ (E) as
shown above.
2. Remove the plastic stopper from the bottom of the dome cap and keep the M20 hex
nut for later use.
3. Depending on the number of wires, remove seals (C) from the rubber seal (B).
4. If you have external devices such as sensors and alarms, feed IO wires through the
waterproof connector (E --> D --> B --> A) as illustrated below. Note that there are 16
holes on the seal (B), and wire range is beteen 1.2 and 1.8mm.
5. Push the seal (B) into the housing (D).
6. Secure the sealing nut (E) tightly.
M20 hex
nut

3-2-2. Connect cables:

1. Use a small-size flat-blade screwdriver to secure IO
wires to the included terminal blocks. You may aslo
purchase an IO combo cable from VIVOTEK.
AC24V
DI GND
AC24V
DI4
Reserved
DI3
MIC IN
DI2
Line OUT
DI1
Audio GND
DO2
RS485-
DO1
RS485+
DO+(12V)
AC24V
DI GND
AC24V
DI4
Reserved
DI3
MIC IN
DI2
Line OUT
DI1
Audio GND
DO2
RS485-
DO1
RS485+
DO+(12V)
(A)
(B)
(D)
(C)
(D)
(B)
Wire range: 13~16AWG
Strip length: 6~7mm
Screw: M2
EN-5
(E)
The max. output load on
DO pins is 50mA.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sd83x6e

Table of Contents