B INSTRUCTIONS FOR THE INSTALLER/MAINTENANCE PERSON
Install a disconnecting switch with a capacity at
least equal to that given in the technical data table,
a 30mA residual current circuit breaker and an
overcurrent device (magnetothermal cut-out with
manual reset or fuse) between the appliance and
the mains power outlet.
The chosen device must be lockable in the open
position in case of maintenance.
MOVING THE MACHINE WITH THE
DOOR
OPEN
WITHOUT TAKING INTO ACCOUNT ITS
ACTUAL WEIGHT OR CENTRE OF
GRAVITY IS EXPRESSLY FORBIDDEN
(DANGER OF TIPPING OVER).
RATING PLATE
The rating plate contains identification and technical
data and is located on the right-hand side panel of the
appliance (Fig. 5).
Fig. 5
B1
WATER CONNECTION
Position the dishwasher and level the appliance by
turning the relative height-adjustable feet (Fig. 5).
Connect the appliance water supply pipe "A"
(Fig. 4) to the mains, fitting a cut-off cock, the filter
provided and a pressure gauge between the appli-
ance and the mains (Fig. 6).
!
Fig. 6
Check that the dynamic water supply pressure,
measured between the appliance and the main, is
between 200 and 300 kPa for machines with pres-
sure boiler and between 50 and 700 kPa for
machines with atmospheric boiler (test while dish-
washer tank or boiler is filling with water). If the
OR
GRIPPING
IT
Model LS7E
PNC 9CGX 500100 05 Ser.N .523000001
AC 400V 3N
50Hz
Power Boiler
16500w
Power Tank
7500w
Power Max
26800w
Made in EU
Model LS7E
PNC
9CGX500100 05
Ser.N .523000001
pressure is too high, fit a suitable pressure
reducer on the inlet pipe.
-
On the model with free-fall drainage:
connect the waste outlet pipe "C" (Fig. 4) to the main
drain pipe, fitting a trap, or place the outlet pipe over an
"S" trap set into the floor.
-
On the model with drain pump:
position the outlet pipe at a height anywhere between
750 and 1000 mm from the floor.
Check that about 4 litres of water flow out of the outlet
pipe during the rinse cycle.
B2
ELECTRICAL CONNECTION
7
8
9
10
11
12
Fig. 7
CAUTION
!
THE EARTH AND ELECTRICAL CON-
NECTIONS SHOULD BE IN COMPLI-
ANCE WITH NATIONAL REGULATIONS.
Before carrying out the electrical connection, check
that the voltage and frequency on the appliance rat-
ing plate correspond to those of the mains electric-
ity supply.
The earth wire at the terminal end must be longer
(max. 20 mm) than the phase wires.
Connect the earth wire of the power supply cable to
an efficient earth clamp. The appliance must also
be included in a unipotential system, the connec-
tion being made through the screw "Q" (Fig. 4)
marked with the symbol "
must have a cross section of 10 mm
1
2
3
4
5
6
. .
0 . .
4 0
A C
". The unipotential wire
2
.