PAC P 9

Start and stop

Starting the engine
1.
Turn the engine switch (A) to position 1.
2.
Turn on the fuel by setting the fuel ON/OFF
control (B) to the ON position.
3.
Move the choke control (C) to the CLOSE
position. If the engine is warm, or the air
temperature high, the choke control should
be set to the OPEN position.
4.
Set the hydraulic by-pass valve to the OFF
position.
5.
Pull the starter grip (E) lightly until resistance
is felt, then pull briskly.
6.
As the engine warms up, gradually move the
choke control (C) to the OPEN position.
Stopping the engine
1.
Turn the engine switch (A) to position 0.
2.
Turn off the fuel by setting the ON/OFF
control (B) to the OFF position.
339 518 83