Maintenance
EMU29320
Checking battery (for electric start
models)
EWM00330
WARNING
Battery electrolytic fluid is dangerous; it
contains sulfuric acid and therefore is poi-
sonous and highly caustic.
Always follow these preventive measures:
Avoid bodily contact with electrolytic
G
fluid as it can cause severe burns or per-
manent eye injury.
Wear protective eye gear when handling
G
or working near batteries.
Antidote (EXTERNAL):
SKIN - Flush with water.
G
EYES - Flush with water for 15 minutes
G
and get immediate medical attention.
Antidote (INTERNAL):
Drink large quantities of water or milk
G
followed by milk of magnesia, beaten
egg, or vegetable oil. Get immediate
medical attention.
Batteries also generate explosive hydro-
gen gas; therefore, you should always fol-
low these preventive measures:
Charge batteries in a well-ventilated ar-
G
ea.
Keep batteries away from fire, sparks, or
G
open flames (for example: welding
equipment, lighted cigarettes, and so
on.)
DO NOT SMOKE when charging or han-
G
dling batteries.
KEEP BATTERIES AND ELECTROLYTIC
FLUID OUT OF REACH OF CHILDREN.
ECM00360
CAUTION:
A poorly maintained battery will quickly
G
deteriorate.
70
Ordinary tap water contains minerals
G
harmful to a battery, and should not be
used for topping up.
1.
Check the electrolyte level at least once a
month. Fill to the manufacturer's recom-
mended level when necessary. Top up
only with distilled water (or pure de-ion-
ized water suitable to use in batteries).
2.
Always keep the battery in a good state of
charge. Installing a voltmeter will help
you monitor your battery. If you will not
use the boat for a month or more, remove
the battery from the boat and store it in a
cool, dark place. Completely recharge
the battery before using it.
3.
If the battery will be stored for longer than
a month, check the specific gravity of the
fluid at least once a month and recharge
the battery when it is low.
NOTE:
Consult a Yamaha dealer when charging or
re-charging batteries.
EMU29332

Connecting the battery

EWM00570
WARNING
Mount the battery holder securely in a dry,
well-ventilated, vibration-free location in
the boat. Install a fully charged battery in
the holder.