Installing The Discharge Chute; Installing The Chute Control Gear - Toro 38086 Operator's Manual

Hide thumbs Also See for 38086:
Table of Contents

Advertisement

Figure 10
1. Hex flange nut
2. Flange locknut
3. Upper control rod
5. Check the distance between the top of the handgrip
and the bottom of the auger/impeller control lever
(Fig. 11). The distance should be approximately four
inches (10.2 cm).
Figure 11
1. Auger/impeller control
lever
2. Handgrip
6. Press the auger/impeller control lever slowly toward
the handgrip. The amount of force to compress the
lever will increase noticeably when you remove the
slack from the drive belt (approximately one-half of
lever movement). The adjustment is correct when the
force begins to increase and the distance between the
top of the handgrip and the bottom of the
auger/impeller control lever is two inches (5.1 cm).
Note:
If the force does not noticeably increase, remove
the belt cover (refer to Replacing the Auger/ Impeller
Drive Belt, steps 1 and 2, on page 21) and measure the
one- to two-inch (2.5 to 5.1 cm) dimension above the
handgrip at the point where there is no slack in the auger
drive belt.
m-2676
4. Lower control rod
5. Lower link
m-2628
3. Approximately four inches
(10.2 cm)
4. Two inches (5.1 cm)
7. Adjust the two flange locknuts, if necessary, to obtain
this dimension.
8. Tighten the two flange locknuts securely (Fig. 10).

Installing the Discharge Chute

1. Apply a light coat of low-temperature grease to the
chute ring.
2. Set the discharge chute (open side forward) onto the
auger discharge opening so that the plastic chute
retainers are on the chute ring (Fig. 12).
3. Tighten the machine screw and the locknut on the left
side to position the plastic chute retainer against the
chute retainer plate and to secure the discharge chute
to the chute ring (Fig. 12).
4. Push the chute retainers on the right side toward the
discharge chute (slotted) and tighten the machine
screw (Fig. 12).
5. Ensure that the chute rotates freely on the chute ring.
If the chute binds, move the right-hand retainer
outward (Fig. 12).
1. Discharge chute
2. Plastic chute retainer
Installing the Chute Control
Gear
1. Remove the two screws from the chute control rod
bracket on left side of the frame (Fig. 13).
2. Remove the chute control rod bracket.
3. Insert the chute control rod through the hole in the
bracket.
4. Install the bracket with the two screws (Fig. 13).
10
m-168
Figure 12
3. Chute retainer plate
4. Chute ring

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

824 xl power throw

Table of Contents