Table Of Contents; Safety Considerations - Daikin FXDQ20NVE Installation Manual

Vrv system inverter air conditioners
Hide thumbs Also See for FXDQ20NVE:
Table of Contents

Advertisement

VRV SYSTEM Inverter Air Conditioners
CONTENTS
1. SAFETY CONSIDERATIONS ......................................... 1
2. BEFORE INSTALLATION................................................ 2
3. SELECTING INSTALLATION SITE ................................. 3
5. INDOOR UNIT INSTALLATION....................................... 5
6. REFRIGERANT PIPING WORK ..................................... 5
7. DRAIN PIPING WORK .................................................... 6
8. INSTALLING THE DUCT................................................. 8
9. ELECTRIC WIRING WORK ............................................ 8
10. WIRING EXAMPLE ......................................................... 9
11. FIELD SETTING AND TEST RUN .................................11
1.

SAFETY CONSIDERATIONS

Please read these "SAFETY CONSIDERATIONS" carefully
before installing air conditioning equipment and be sure to
install it correctly.
This air conditioner comes under the terms "appliances not
accessible to the general public".
The safety precautions listed here are divided into two catego-
ries. In either case, important safety information is listed which
must be read carefully.
WARNING ............. Failure to observe a warning may
result in death or serious injury.
CAUTION .............. Failure to observe a caution may
result in injury or material damage due
to erroneous handling including prob-
abilities leading to serious conse-
quences in some cases.
After completing the installation, make sure that the unit oper-
ates properly during the start-up operation. Please instruct the
customer on how to operate the unit and keep it maintained.
Also, inform customers that they should store this installation
manual along with the operation manual for future reference.
WARNING
• Ask your dealer or qualified personnel to carry out installa-
tion work. Do not try to install the air conditioner yourself.
Improper installation may result in water leakage, electric
shocks or fire.
• Perform installation work in accordance with this installation
manual.
Improper installation may result in equipment falling, water
leakage, electric shocks or fire.
• When installing the unit in a small room, take measures
against to keep refrigerant concentration from exceeding
allowable safety limits in the event of refrigerant leakage.
Contact the place of purchase for more information.
Excessive refrigerant in a closed ambient can lead to oxygen
deficiency.
• Be sure to use only the specified accessories and parts for
installation work.
Failure to use the specified parts may result in water leakage,
electric shocks, fire or the unit falling.
• Install the air conditioner on a foundation strong enough to
withstand the weight of the unit.
A foundation of insufficient strength may result in the unit fall-
ing and causing injuries.
• Carry out the specified installation work after taking into
account strong winds, typhoons or earthquakes.
Improper installation work may result in the unit falling and
causing accidents.
English
• Make sure that a separate power supply circuit is provided
for this unit and that all electrical work is carried out by qual-
ified personnel according to local laws and regulations and
this installation manual.
An insufficient power supply capacity or improper electrical
construction may lead to electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used,
and no external forces act on the terminal connections or wires.
Improper connections or installation may result in fire.
• When wiring the power supply and connecting the remote
controller wiring and transmission wiring, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in elec-
tric shocks, fire or the terminals overheating.
• If the refrigerant gas leaks during installation, ventilate the
area immediately.
Toxic gas may be produced if the refrigerant gas comes into
contact with fire.
• After completing the installation work, check that the refriger-
ant gas does not leak.
Toxic gas may be produced if the refrigerant gas leaks into
the room and comes into contact with a source of fire, such
as a fan heater, stove or cooker.
• Before touching electrical parts, turn off the unit.
• Do not touch the switch with wet fingers.
Touching the switch with wet fingers can cause electric shock.
• Be sure to establish an earth.
Do not earth the unit to a utility pipe, arrester, or telephone
earth.
Incomplete earth may cause electrical shock, or fire.
A high surge current from lightning or other sources may
cause damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in elec-
tric shocks, or fire.
CAUTION
• While following the instructions in this installation manual,
install drain piping in order to ensure proper drainage and
insulate piping in order to prevent condensation.
Improper drain piping may result in water leakage and prop-
erty damage.
• Install the indoor and outdoor units, power supply wiring and
connecting wires at least 1 m away from televisions or radios
in order to prevent image interference or noise.
(Depending on the radio waves, a distance of 1 m may not be
sufficient enough to eliminate the noise.)
• Remote controller (wireless kit) transmitting distance can
result shorter than expected in rooms with electronic fluores-
cent lamps. (inverter or rapid start types)
Install the indoor unit as far away from fluorescent lamps as
possibe.
• Do not install the air conditioner in the following locations:
(a) where a mineral oil mist or an oil spray or vapor is pro-
duced, for example in a kitchen.
Plastic parts may deteriorate and fall off or result in
water leakage.
(b) where corrosive gas, such as sulfurous acid gas, is produced
Corroding copper pipes or soldered parts may result in
refrigerant leakage.
(c) near machinery emitting electromagnetic waves
Electromagnetic waves may disturb the operation of the
control system and result in a malfunction of the unit.
(d) where flammable gas may leak, where there are carbon
fiber or ignitable dust suspensions in the air, or where vol-
atile flammables such as thinner or gasoline are handled.
Operating the unit in such conditions may result in fire.
Installation manual
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents