Fisher & Paykel RF135B Installation Instructions And User Manual page 16

Table of Contents

Advertisement

ImpORTANT!
All connections must be checked for leaks.
Ensure white ¼" (6 mm) tubing is routed away from sharp objects, sharp corners
(beware of kinking the tube as this will stop water flow), clear of the refrigerator rear
compartment and not in a location where it can be kinked or squashed.
Ensure all push-fit connections are firmly pushed into place. The tube should push in
5/8" (16 mm) before reaching the stop.
If tubing is removed at any point, re-cut the end and re-insert. Tubing must be fully
inserted to avoid leaks.
To remove tube from connection points first turn off the isolating faucet. gently push
PART: 838587
the dispensing pad a few times using a glass or container to remove the static line
6
7
pressure. push in the collet firmly while pulling back on the tubing at the same time,
as shown in diagram 10.
System tested and certified by NSF International against NSF/ANSI Standard 53 for the
reduction of Asbestos, Atrazine, Benzene, Cyst, Carbofuran, Lead, Lindane, Mercury,
P-Dichlorobenzene, Toxaphene & Turbidity; against Standard NSF/ANSI 42 for the
reduction of Chlorine Taste and Odor and Nominal Particulate Class I to a capacity of
750 gallons (2,838 liters).
16
INSTALLATION INSTRUCTIONS
DRAWING: 838587
8
9
Diagram 11
Connection to water supply
Diagram 10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rf170wRf170aRf201aRf135bdlx4

Table of Contents