Putting an open flame beside a new gas connection is extremely dangerous.
DO NOT USE APPLIANCE DURING PROLONGED POWER FAILURE AS THE VENT HOOD MAY NOT BE IN
OPERATION RESULTING IN INADEQUATE VENTING!
INITIAL PILOT LIGHTING:
CAUTION: When lighting pilots and checking for leaks, do not stand with your face close to the
combustion chamber.

Check for Gas Leaks:

1. Remove the kick plate and the component cover at the rear of the oven
2. Check pilot tubing and burner tubing for leaks at the connectors with a soapy water solution.
3. Light the pilot as described above.
4. Turn the thermostat to any setting and the burner should light.
5. Check the burner orifice elbow connection downstream of the valve with a soapy water
solution.
6. Check the burner visually for blue flame. There should be no yellow tips or soot. If yellow tipping
occurs, call an authorized service person to adjust the burner air shutter.

Disclaimer:

All MARKET FORGE INDUSTRIES, INC. appliances are adjusted and tested before leaving the factory,
effectively matching them to sea level conditions. Adjustments and calibrations to assure proper
operation may be necessary on installation to meet local conditions; low gas characteristics, to correct
possible problems caused by rough handling or vibration during shipment, and are to be performed only
by qualified service personnel. These adjustments are the responsibility of the customer and/or dealer
and are not covered by our warranty.
INSTALLATION
DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS!