Type UCCG, UCDG
57611C 08/09 (DJU)
Product program
This user manual covers following thermostats with built-in GFCI
UCCG-9991
Incl. floor sensor 3m (10ft), 120Vac 50/60 Hz supply.
UCCG-9999
With built-in room sensor, 120/240Vac 50/60 Hz supply.
UCDG-9999
With 2 sensors; built-in room sensor and incl. floor sensor 3m (10ft), 120Vac 50/60 Hz supply.
Introduction
The thermostat is an electronic on/off thermostat for control of temperature by means of an NTC sensor either placed externally or internally in the thermostat.
The thermostat has integrated a Ground Fault Circuit Interrupter (GFCI).
The thermostat is capable of switching on your heating system at pre determined times on different days of the week. It is possible to set 4 periods called events
each day with different temperatures. From factory a default schedule is programmed suitable for most installations. Unless you change these settings the
thermostat will operate to this default program. Working with lower temperatures during times that the room is unoccupied will lower your energy costs without
reducing the comfort. The thermostat has an adaptive function that automatically changes the start time of a heating period so that the desired temperature is
reached at the time that you set. After 5 days the adaptive function has learned when the heating must be switched on.
The thermostat type UCCG-9991 has an external temperature sensor that is normally placed in the floor construction. In this configuration the thermostat
controls the temperature of the floor and not the temperature within the room.
The thermostat type UCCG-9999 has a built-in temperature sensor. In this configuration the thermostat controls the temperature of the room.
The thermostat type UCDG-9999 has a built-in temperature sensor and an external temperature sensor. In this configuration the thermostat controls the
temperature within the room and use the external temperature sensor as limit sensor avoiding too high or too low temperatures in the floor construction.
The thermostat has a pin button marked R, allowing you to reset the thermostat to factory settings. These are listed at the end of this manual with space for
you to record your own weekly schedule.
1. Getting started
Buttons
®
A
Reset
B
GFCI
C
Test
R
D
E
A:
B:
Reset of GFCI
Red light
indicating
ground fault
Setting the thermostat into operation
First time power is connected the clock and day will be flashing and must be set. After setting of time and day, selection of time scale (12 h or 24 h) and
temperature scale (°C or °F) can be selected. If you need to adjust the time of the thermostat at a later date, insert a pin into the hole (
day. Adjustment must be made for summer and winter time. Setting of time and temperature scale can also be done under "advanced settings and read-out see 4.
Press the UP (
select the correct time and press OK button (
Then press the UP (
select the correct day and press OK (
Press the UP (
temperature scale and press OK (
D:
Pin button
adjust of clock
E:
Display
F:
I
Reset to factory
H
setting
G
G:
Adjustment down
F
H:
OK - accept
I:
Adjustment up
C:
Test of GFCI
) or DOWN (
) buttons to
) or DOWN (
) button to select time and
) button.
Display symbols
J:
Clock
function
).
) button to
1-7
) button.
© 2009 OJ Electronics /S
J
K
L
M
K:
L:
Manual
Time and
mode
temperature
N:
Heating on
O: %
Monitoring of
switch-on time
P
P:
4-event
symbol:
O
Wake
Night
N
Out
Home
M:
Day
number
) for setting of time and
1

Advertisement

loading

Summary of Contents for OJ Electronics UCCG

  • Page 1 After 5 days the adaptive function has learned when the heating must be switched on. The thermostat type UCCG-9991 has an external temperature sensor that is normally placed in the floor construction. In this configuration the thermostat controls the temperature of the floor and not the temperature within the room.
  • Page 2 The temperature can be set within the range of +41°F to +104˚F. : Time and temperature It is also possible to select the heating OFF at that event by reducing the setting to 41˚F, and then pressing the ( ) once more. : Time and temperature © 2009 OJ Electronics /S...
  • Page 3 77˚F is achieved by 07:00 a.m. Without this function set, the thermostat will start to heat at the time you set. Press the DOWN ( ) button to switch between on and off. Press OK ( ) button to confirm. Press OK ( ) button to end programming and to return to scheduled programme. © 2009 OJ Electronics /S...
  • Page 4 Stenager 13B · DK-6400 Sønderborg Tel. +45 73 12 13 14 · Fax +45 73 12 13 13 oj@oj.dk · www.oj.dk © 2009 OJ Electronics /S - ® The OJ trademark is a registred trademark belonging to OJ Electronics /S...
  • Page 5 Le modèle de thermostat UCCG-9991 est muni d'un capteur de température externe que l'on place normalement dans le plancher. De cette façon, le thermostat contrôle la température du plancher et non celle de la pièce.
  • Page 6 La plage de température est réglable de 41°F à 104°F. Il est également possible de mettre le chauffage hors circuit : Heure et température pour cet événement en réduisant la température à 41°F et en appuyant sur la touche ( ) à nouveau. © 2009 OJ Electronics /S...
  • Page 7 Appuyez sur la touche OK ( ) pour confirmer. Appuyez sur la touche OK ( ) pour mettre fin à la programmation et revenir à l'horaire programmé. © 2009 OJ Electronics /S...
  • Page 8 OJ ELECTRONICS A/S Stenager 13B · DK-6400 Sønderborg Tel. +45 73 12 13 14 · Fax +45 73 12 13 13 oj@oj.dk · www.oj.dk © 2009 OJ Electronics /S - ® OJ est une marque déposée de OJ Electronics /S...
  • Page 9 Después de 5 días la función adaptativa habrá aprendido a qué hora deberá activarse la calefacción. El termostato tipo UCCG-9991 tiene un sensor de temperatura externo que normalmente se coloca en la construcción del piso. En esta configuración el termostato controla la temperatura del piso y no la temperatura ambiente en la habitación.
  • Page 10 +41 °F a +104 °F. Además es posible seleccionar el apagado (OFF) de la calefacción al reducir el valor de ajuste a 41 °F, y después pulsar el ( ) una vez más. : Hora y temperatura © 2009 OJ Electronics /S...
  • Page 11 Pulse el botón DOWN ( ) para alternar entre encendido y apagado. Pulse el botón OK ( ) para confirmar. Pulse el botón OK ( ) para terminar la programación y regresar al horario programado. © 2009 OJ Electronics /S...
  • Page 12 Stenager 13B · DK-6400 Sønderborg Tel. +45 73 12 13 14 · Fax +45 73 12 13 13 oj@oj.dk · www.oj.dk 5 7 6 1 1 C © 2009 OJ Electronics /S - ® OJ es una marca comercial registrada de OJ Electronics /S...

This manual is also suitable for:

Ucdg