Technical Data - Baxi System 100 HE Plus Installation & Servicing Instructions Manual

Wall mounted powered flue condensing gas fired central heating boiler
Table of Contents

Advertisement

Appliance Type
C
Appliance Category
CAT I
Heat Input Gross
Max
kW
33.76
Btu/h
115,200
Heat Output
(Non Condensing 70° C Mean Water Temp)
Max
kW
30.18
Btu/h
102,980
Heat Output
(Condensing 40° C Mean Water Temp)
Max
kW
32.61
Btu/h
111,280
Max Gas Rate
(Natural Gas)
(After 10 Mins)
Btu/hr
102,980
3
m
/h
2.95
ft
3
/h
104.2
Inlet Pressure (Natural Gas)
Min
18.1 mbar
Max
22.5 mbar
(see Section 10.1)
Injector (Natural Gas)
6.3mm Diameter
No x Class
5
CO/CO
Ratio
0.001
2
SEDBUK Declaration For
Baxi System 100 HE Plus
The seasonal efficiency (SEDBUK) is 90.9 %
This value is used in the UK Government's Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by 0086.
NOTE: The maximum output of the
boiler is factory set at 22.0kW (75,000
Btu/hr). This can be altered to 30.18kW
(102,980 Btu/hr)
- see section 8.7.
C
Connections
13
33
Gas Supply
Central Heating Flow
2H
Central Heating Return
Min
Pressure Relief Discharge
10.2
Condensate Drain
34,840
Outercase Dimensions
Overall Height
Casing Height
Casing Width
Min
Casing Depth
9.14
31,180
Clearances
(For unventilated compartments see Section 7.2)
Both Sides
Above Casing
Min
Below Casing
10.1
Front (For Servicing)
Front (In Operation)
34,520
Weights
Packaged Boiler Carton
Packaged Flue Kit
75,000
Weight Empty
2.36
Installation Lift Weight
83.3
Recommended System
Temperature Drop
Condensing
Central Heating Primary
Circuit Pressures
Safety Discharge
Max Operating
Min Operating
Recommend Operating

4.0 Technical Data

compression
-
1
/
" BSPF
2
-
22mm
-
22mm
-
15mm
-
1" BSP
-
1000mm
Inc Flue Elbow
-
850mm
-
490mm
-
320mm
5mm Min
200mm Min
200mm Min
500mm Min
5mm Min
kg
lb
53.6
118
3.6
8.0
48.6
107
40.2
88.6
20°C
36°F
bar
lb/in
2
3
43.5
2.5
36.3
0.7
10.2
1-2
14.5-29
Central Heating Circuit available Pump Head
600
500
400
300
200
100
0
0
120
240
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Power Consumption
200W
External Fuse Rating
3A
Internal Fuse Rating (BS 4265)
Fuse
3.15 AT (PCB)
Electrical Protection
IPX2
Water Content
litres
3.5
pints
6.2
Expansion Vessel
- (For Central Heating only.
Integral with appliance)
bar
Min Pre-charge Pressure
0.95
Nominal Pre-charge
Pressure
1
litre
Max Capacity of
CH System
125
Controls
boiler thermostat, safety thermostat,
flow switch, electronic flame sensing,
temperature protection thermostat &
condensate blockage sensor.
Horizontal
Flue Terminal
Diameter
Dimensions
Projection
360
480
600
Flow Rate (l/h)
lb/in
2
13.6
14.5
gal
27.5
110mm
150mm
720
840
9