Baxi System 100 HE Plus Installation & Servicing Instructions Manual page 22

Wall mounted powered flue condensing gas fired central heating boiler
Table of Contents

Advertisement

Lower Door
Panel
Fig. 22
Fig. 23
22
Outer Case Fixing
Screw
Service Guidance Note Label
on inside of panel
8.0 Installation
8.3
Preparing The Boiler
1. Remove the outer carton.
2. Hinge up the lower door panel (Fig. 22).
3. Remove the outer case fixing screws (Fig. 22). Slide
the outercase upwards to disengage the hooks on the
backplate and remove (Fig. 23).
NOTE: Service Guidance Note Label is fitted to the
inside of the outercase (Fig. 23).
4. Remove the sealing plugs from the copper bends.
5. Remove cardboard transit packaging at the left hand
rear of the boiler before lifting the boiler onto the
support bracket.
6. Stand the boiler on its base by using the rear lower
edge as a pivot.
NOTE: A small amount of water may drain from the
boiler in the upright position.
Baxi declare that no substances harmful to health
are contained in the appliance or used during
construction of the appliance.