Built-in coffee system
Table of Contents

Advertisement

Problem
The door is difficult to
open and close.
The coffee system does
not rinse itself when
turned on.
During rinsing, no or
considerably less rins‐
ing water than usual
comes out of the main
dispenser.
No or considerably less
coffee than usual
comes out of the main
dispenser. The displays
and preparation noises
are unchanged.
The waste unit contains
considerably more "cof‐
fee water."
Frequently Asked Questions
Possible cause and solution
The cap of the main dispenser connector is not suffi‐
ciently greased. The silicone cap gets jammed in the
brew unit.
Check the silicone cap for damage. Repalce the
cap with the provided spare part if necessary.
Lubricate the cap with the included silicone
grease.
Grease the cap of the main dispenser connector reg‐
ularly, at least once a month.
This is not a fault.
If the coffee system still has an operating tempera‐
ture higher than 140°F (60°C), rinsing will not take
place.
The main dispenser is not correctly mounted.
Make sure the main dispenser has been assem‐
bled as described (see "Cleaning and care – Main
dispenser").
The cap is no longer sitting firmly on the main dis‐
penser connector (see "Guide to the appliance").
Check the cap of the main dispenser connector.
Grease the cap with the included silicone grease.
The cap of the main dispenser connector is damaged
or missing.
Replace the cap with the provided spare part.
Lubricate the cap with the included silicone
grease.