Calibrating The Spray Pro Monitor - Toro 41179 Operator's Manual

Turf sprayer
Table of Contents

Advertisement

Calibrating the Spray Pro
Monitor
1. LCD screen
2. Selection dial
3. Total area
4. Speed
5. Units of measure
The Spray Pro monitor has a calibration mode that
allows you to change various settings to customize the
display and calibrate the monitor to your needs. You
can calibrate or change the following settings:
• Boom Width
• Units of Measure
• Speed
• Flowmeter
Setting the Boom Width
The default settings for the boom widths are 80 inches
(2.03 m) for the right and left booms and 60 (1.524 m)
for the center boom. This is based on 4 nozzles on
the right and left booms and 3 on the center boom all
spaced 20 inches (50.8 cm) apart. If you change the
spacing of the nozzles, you should change the boom
width to reflect your changes as follows:
1. Stop the sprayer and set the parking brake.
2. Set the master boom switch to the Off position.
The monitor displays "HOLD".
6. Application rate
7. Sub Area
8. Distance
9. Sub volume
10. Total volume
Figure 28
11. Reset, calibration button
12. Calibrate, calibration button 17. Width
13. Decrease, calibration button 18. Speed calibration
14. Increase, calibration button 19. Flowmeter calibration
15. Boom selection
3. Press and hold the Calibrate button until the
monitor displays "CAL HOLD" and the red light
on the monitor illuminates.
4. Turn the selection dial to the Boom Select (or Total
Area) position.
5. Use the Increase or Decrease calibration buttons
to select the boom for which you wish to change
the width, where 1 is the left boom, 2 is the center
boom, and 3 is the right boom.
6. Turn the selection dial to the Width (or Sub Area)
position.
7. Use the Increase or Decrease calibration buttons to
change the boom width as needed.
8. Repeat steps 4 through 7 for the other booms as
needed.
9. Press the Calibrate button until the red light turns
off. You can also exit the calibration mode by
driving the sprayer.
Setting the Units of Measure
The default setting for the units of measure is US. You
can also change the units to SI (metric) or TURF.
32
16. Select units
20. LED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi-pro 1250

Table of Contents