Convection Bake Element Removal; Broil Element Removal; Control Components Accessed; Control Panel Assembly Removal - Viking RDSCD230-5B Service Manual

30 inch dual fuel range
Hide thumbs Also See for RDSCD230-5B:
Table of Contents

Advertisement

To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Convection Bake Element Removal

1. Remove convection fan cover (see Convection Fan
Cover Removal).
2. Remove screws that attach the convection bake
element to the oven liner.
3. Mark and disconnect wires from convection element.
4. Reverse procedure for installation.

Broil Element Removal

1. Remove oven door (see Door Assembly Removal).
2. Remove screws and bracket from broil assembly.
3. Remove screws that hold the broil assembly to the
back of the oven liner.
4. Remove screws that hold the broil assembly to the
top of the oven liner.
Note: Use care when pulling broil assembly into the
oven cavity. Make sure the connectors remain
on the broil assembly.
5. Carefully pull connectors through the oven cavity wall
and lower the broil assembly.
6. Mark and disconnect connectors from broil element.
Note: During installation, make sure broil connectors
go back through the oven liner.
7. Reverse procedure for installation.
©2012 Viking Preferred Service

Control Components Accessed

1. Remove oven door (see Door Assembly Removal).
2. Remove all surface burner knobs.
3. Remove screws and bezels from control panel
assembly where knobs have been removed.
4. Remove screws from below control panel assembly.
5. Lift up to remove control panel assembly from
keyhole screws.
6. Place control panel assembly on protective surface
on the top of range.
7. Reverse procedure for installation.

Control Panel Assembly Removal

1. Access control components (see Control
Components Accessed).
2. Mark and disconnect all connectors to remove control
panel from range.
3. Reverse procedure for installation.
Disassembly