– If one reading is around 0.5 and the other reading is ʻOLʼ,
the diode is good
– If both readings are ʻOLʼ, the diode is open (defective)
– If both readings are very small or 0 (zero), the diode is
shorted (defective)

6. FREQUENCY MEASUREMENT

WARNING:
THAN 250V.
➔ Set the function switch to VOLT/Hz/%.
➔ Press Hz/% button once and ʻHzʼ appears on the display.
➔ Apply the test leads to the point of measurement.
➔ Read the displayed frequency indicated with proper decimal point
and symbol.

7. CAPACITANCE MEASUREMENT

WARNING:
CAPACITOR LEADS TOGETHER BEFORE TESTING.
NOTE: The meter is auto ranging and will automatically display the correct
capacitance value within the overall range of the meter.
➔ Set the function switch to
➔ Press the Select button until ʻFʼ appears on the display.
➔ Touch the probe tips to the capacitor.
➔ Read the value and unit shown on the display.
NEVER MEASURE FREQUENCY ON A CIRCUIT WITH MORE
FULLY DISCHARGE THE CAPACITOR BY SHORTING THE
/ / /
.