6
1. Wing nut
2. Battery cover
3. Negative (–) battery cable
Charging the Battery
WARNING
Charging the battery produces gasses that can
explode.
Never smoke near the battery and keep sparks and
flames away from battery.
Important: Always keep the battery fully charged
(1.265 specific gravity) to prevent battery damage when
the temperature is below 32°F (0°C).
1. Remove the battery from the chassis; refer to
the Battery (page
38).
2. Check the electrolyte level.
3. Ensure that the filler caps are installed on the battery.
4. Charge the battery for 1 hour at 25 to 30 amps or 6
hours at 4 to 6 amps.
5. When the battery is fully charged, unplug the charger
from the electrical outlet, and disconnect the charger
leads from the battery posts
2
3
4
Figure 51
4. Positive (+) battery cable
5. Battery
6. The battery cables cross
when installed correctly
(Figure
52).
6. Install the battery onto the machine and connect the
battery cables; refer to
Note: Do not run the machine with the battery
disconnected; electrical damage may occur.
1. Positive Battery Post
2. Negative Battery Post

Servicing the Fuses

The electrical system is protected by fuses. It requires no
g013199
maintenance. If a fuse blows, check the component or circuit
for a malfunction or short.
1. Release the operator cushion from the rear of the
machine.
2. Pull out on the fuse to remove and replace it
53).
3. Install the operator cushion.
Removing
1. Controls
2. Wire
39
Installing the Battery (page
Figure 52
3. Red (+) Charger Lead
4. Black (-) Charger Lead
Figure 53
3. Fuses
38).
(Figure
g013015

Advertisement