2. Install the positive (red) battery cable to the
positive (+) battery terminal.
3. Install the negative battery cable to the negative
(-) battery terminal.
4. Secure the cables with 2 bolts (1/4 x 3/4 inch),
washers (1/4 inch), and nuts (1/4 inch)
(Figure 34).
5. Slide the red terminal boot onto the positive
(red) battery post.
6. Secure the battery with the hold-down
(Figure 34).
Checking the Electrolyte Level
Battery electrolyte contains sulfuric acid
which is a deadly poison and causes severe
burns.
• Do not drink electrolyte and avoid
contact with skin, eyes or clothing. Wear
safety glasses to shield your eyes and
rubber gloves to protect your hands.
• Fill the battery where clean water is
always available for flushing the skin.
1. Tip the seat forward to see the battery.
2. Look at the side of the battery. The electrolyte
must be up to the Upper line (Figure 35).
Do not allow the electrolyte to fall below the
Lower line (Figure 35).
Figure 35
1. Vent caps
2. Upper line
3. If the electrolyte is low, add the required
amount of distilled water; refer to Adding
Water to the Battery.
3. Lower line
Adding Water to the Battery
The best time to add distilled water to the battery is
just before you operate the machine. This lets the
water mix thoroughly with the electrolyte solution.
1. Remove the battery from the tractor; refer to
Removing the Battery.
Important: Never fill the battery with
distilled water while the battery installed in
the tractor. Electrolyte could be spilled on
other parts and cause corrosion.
2. Clean the top of the battery with a paper towel.
3. Remove the vent caps from the battery
(Figure 35).
4. Slowly pour distilled water into each battery
cell until the electrolyte level is up to the Upper
line (Figure 35) on the battery case.
Important: Do not overfill the battery
because electrolyte (sulfuric acid) can
cause severe corrosion and damage to the
chassis.
5. Wait five to ten minutes after filling the battery
cells. Add distilled water, if necessary, until
the electrolyte level is up to the Upper line
(Figure 35) on the battery case.
6. Reinstall the battery vent caps.

Charging the Battery

Important: Always keep the battery
fully charged (1.260 specific gravity). This
is especially important to prevent battery
damage when the temperature is below 32°F
(0°C).
1. Remove the battery from the chassis; refer to
Removing the Battery.
2. Check the electrolyte level; refer to Checking
the Electrolyte Level.
3. Make sure that the vent caps are installed in
the battery. Charge the battery for 1 hour at 25
to 30 amps or 6 hours at 4-6 amps. Do not
overcharge the battery.
4. When the battery is fully charged, unplug
the charger from the electrical outlet, then
disconnect the charger leads from the battery
posts (Figure 36).
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

74407Timecutter zx440Timecutter zx525

Table of Contents