Fuel Filter

Replace the fuel filter after every 200 operating hours
or yearly, whichever occurs first.
Replacing the Fuel Filter
Never install a dirty filter if it is removed from the
fuel line.
1.
Disengage the power take off (PTO) and turn the
ignition key to "OFF" to stop the engine.
Remove the key.
2.
Close fuel shut–off valve at fuel tank (Fig. 25).
3.
Squeeze the ends of the hose clamps together
and slide them away from the filter (Fig. 26).
4.
Remove the filter from the fuel lines.
5.
Install a new filter and move the hose clamps
close to the filter.
6.
Open fuel shut-off valve at fuel tank (Fig. 25).
Figure 26
1. Hose clamp
2. Fuel line
3
1
3. Filter

Hydraulic System

Checking the Hydraulic Fluid
Check the hydraulic fluid level before engine is first
started and after every 8 operating hours.
Fluid Type: Mobilube 424 (ISO 68) or equivalent
anti–wear hydraulic fluid.
IMPORTANT: Use only hydraulic oils
specified. Other fluids could cause system
damage.
Tank Capacity: 1-3/4 qt. (1.6 l)
1.
Position machine on a level surface and stop the
engine.
2.
Clean area around filler neck and cap\dipstick of
hydraulic tank (Fig. 27).
3.
Remove cap\dipstick from filler neck and wipe
with a clean rag. Insert cap\dipstick and seat cap
all the way into filler neck; then remove and
check fluid level. Fluid level should be in
between marks on dipstick.
4.
If level is low, add fluid to raise level to full
mark.
5.
Install cap\dipstick onto filler neck.
2
m–2596
2
1. Hydraulic tank cap
Maintenance
Figure 27
2. Fuel tank cap\dipstick
1
m–2613
29