WARNING:
Improper installation, adjustment,
alteration, service or maintenance can cause
property damage, injury or death.
the installation, operating and maintenance
instructions thoroughly before installing or
servicing this equipment.
FOR YOUR SAFETY:
gasoline or other flammable vapors or liquids
in the vicinity of this or any other appliance.
Star
Manufacturing
International Inc.
10 Sunnen Drive
St. Louis, MO 63143
Phone: (314) 678-6303
Fax: (314) 781-2714
MODELS
8124RCBA, 8136RCBA,
MODELS
8024CBA, 8036CBA,
Read
Do not store or use
2M-Z16154 Rev. B
WARNING:
This appliance shall be installed
in accordance with current regulations and
used only in well-ventilated space. Refer to
instructions before installing and using this
appliance.
In addition, there should be posted, in a
prominent location, detailed instructions to
be followed in the event the operator smells
gas. Obtain the instructions from the local
gas supplier.
Installation
and
Operating
Instructions
10/05/15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8124RCBA and is the answer not in the manual?

Questions and answers

Summary of Contents for Star Manufacturing 8124RCBA

  • Page 1 Instructions St. Louis, MO 63143 Phone: (314) 678-6303 Fax: (314) 781-2714 2M-Z16154 Rev. B 10/05/15 ULTRA-MAX GAS RADIANT CHARBROILER MODELS 8124RCBA, 8136RCBA, 8148RCBA, 8160RCBA, and 8172RCBA ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBA, 8036CBA, 8048CBA, 8060CBA, and 8072CBA WARNING: WARNING:...
  • Page 2: Safety Symbol

    SAFETY SYMBOL These symbols are intended to alert the user to the presence of important operating and maintenance instructions in the manual accompanying the appliance. RETAIN THIS MANUAL FOR FUTURE REFERENCE NOTICE Using any part other than genuine Star factory supplied parts relieves the manufacturer of all liability.
  • Page 3: Specifications

    Grid Area Controls Installed Shipped Width Depth Height RADIANT 603 sq in 196 lbs 262 lbs 24” 8124RCBA 80,000 (3,890 sq cm) (88.9 kg) (118.9 kg) (61 cm) 906 sq in 273 lbs 349 lbs 36” 8136RCBA 120,000 (5,845 sq cm) (123.8 kg)
  • Page 4: General Installation Data

    GENERAL INSTALLATION DATA This equipment is designed and sold for commercial use only by personnel trained and experienced in its operation and is not sold for consumer use in and around the home nor for use directly by the general public in food service locations. CAUTION The Ultra-Max™...
  • Page 5: Floor Stand Model

    LEVELING UNIT CAUTION This charbroiler is supplied with 4 feet or floor stand legs which must be screwed into the body. Unit must be DO NOT INSTALL WITHOUT ATTACHING FEET level. Level unit by adjusting the (4) feet which have an adjustment of 1-3/4"...
  • Page 6: Pilot Lighting Instructions

    GENERAL INSTALLATION DATA (continued) PLACING RADIANTS - RCBA SERIES After the unit is unpacked and installed, place 1 radiant above each burner. Install each radiant on 2 slots of the rear wall and on 1 pin of the front wall of the liner weld assembly. Refer to the exploded view in this manual for orientation of the radiants.
  • Page 7: Burner Operation

    4. Turn on main valve and light all pilots. 5. Adjust pilot light flames as small as possible, usually about 1/2" high, but high enough to light burner immediately when burner valve is turned on high. 6. Turn burner knobs to desired setting. 7.
  • Page 8: Set Screw

    8-32 x 1/4” or 10-24 x 1/4” SOME ITEMS ARE INCLUDED FOR ILLUSTRATIVE PURPOSES ONLY AND IN 8124RCBA, 8024CBA CERTAIN INSTANCES MAY NOT BE AVAILABLE MODEL: 8124RCBA, 8136RCBA, 8148RCBA STAR MANUFACTURING INTERNATIONAL, INC. 8160RCBA, 8172RCBA SK2607 Rev. B 10/05/15 8024CBA, 8036CBA, 8048CBA...
  • Page 9: Parts List

    8024/8036/8048/8060/8072 Ultra-Max Lava Rock Gas Charbroiler Model: Ultra-Max Gas Charbroiler Radiant & Lava Rock Model: Ultra-Max Gas Charbroiler Radiant & Lava Rock Fig No Part Number Description Application 8124RCBA, 8024CBA 8136RCBA, 8036CBA 8124RCBA, 8024CBA 2A-Z15909 ELBOW 15 DEG. 8148RCBA, 8048CBA...
  • Page 10: Limited Equipment Warranty

    Visit our Website at: www.star-mfg.com Email: customerservice@star-mfg.com THOROUGHLY INSPECT YOUR UNIT ON ARRIVAL This unit has been tested for proper operation before leaving our plant to insure delivery of your unit in perfect condition. However, there are instances in which the unit may be damaged in transit.
  • Page 14 INSTRUCTIONS POUR ÉTEINDRE LE BARBECUE Pour éteindre les brûleurs, tourner les boutons des brûleurs sur la position de fermeture. NETTOYAGE Nettoyer le barbecue régulièrement. Enlever la section du grille et la laver dans l’évier. Enlever à la brosse les particules carbonisées. Enlever et laver le bac à eau. Nettoyer les surfaces extérieures à l’aide d’un chiffon et d’un détergent.
  • Page 15: Instructions De Fonctionnement

    INSTRUCTIONS CONCERNANT LES VEILLEUSES D’ALLUMAGE Le barbecue est équipé de veilleuses stationnaires et il faut l’allumer dès que le bouton de gaz est ouvert. 1. Éteignez la principale valve à unité. 2. Éteignez tous les boutons et valves du pilote et attendez 5 minutes éclaircir du gaz.
  • Page 16 PLAÇANT RADIANTS - RCBA SÉRIE Après que l'unité soit déballée et est installée, placez-en 1 radiant au-dessus de chaque brûleur. Installez chaque radiant sur 2 fentes du mur arrière et sur 1 épingle du mur de devant de l'assemblée de la soudure du paquebot.
  • Page 17 ÉQUILIBRAGE DE L’APPAREIL Ce charbroiler est assuré avec 4 pieds ou jambes de MISE EN stand de plancher qui doivent être vissés dans le corps. GARDE L'unité doit être niveau. Équilibrer l’appareil en ajustant N’INSTALLEZ PAS SANS ATTACHER ES les (4) pieds qui ont un réglage de 1-3/4 po., en vue d’un PIEDS OU DES JAMBES ET L'ETAGERE alignement exact et parfait avec d’autres appareils.
  • Page 18 DONNÉES GÉNÉRALES D’INSTALLATION Cet équipement n’est conçu et vendu que pour l’utilisation commerciale par le personnel formé et sachant l’utiliser et il n’est pas vendu pour l’utilisation à la maison, ni pour l’usage du public dans les endroits de pique-nique. MISE EN Le barbecue de la série Ultra-Max est équipé...
  • Page 19: Entretien Et Réparations

    Dû aux modifications périodiques de dessins, méthodes, procédures, règles et régulations, les spécifications contenues dans ce manuel sont susceptibles de changer sans préavis. Quoique STAR Manufacturing exerce la bonne foi de fournir le renseignement correct, STAR n’est pas responsable pour les erreurs ou les omissions dans le renseignement pourvu ou les conclusions tirées à...
  • Page 20 St. Louis, MO 63143 Phone: (314) 678-6303 Fax: (314) 781-2714 2M-Z16154 Rev. A 10/05/2015 BARBECUE A GAZ RAYONNANT ULTRA-MAX MODELES 8124RCBA, 8136RCBA 8148RCBA, 8160RCBA, et 8172RCBA BARBECUE A GAZ ROCHE DE LAVE ULTRA-MAX MODELES 8024CBA, 8036CBA, 8048CBA, 8060CBA, et 8072CBA AVERTISSEMENT: L’installation inexacte,...