Minimum Dimensions - Samsung NY58J9850WS Installation Manual

Dual fuel range
Hide thumbs Also See for NY58J9850WS:
Table of Contents

Advertisement

Available languages

Available languages

Installation requirements

Minimum dimensions

WARNING
If overhead cabinets are provided, a range
hood should also be provided that projects
horizontally a minimum of 5 in (12.7 cm)
beyond the front of the cabinets. This will
dissipate any heat buildup in the overhead
cabinets to prevent death, personal injury, and/
or fire hazard. The ventilating hood must be
constructed of sheet metal not less than 0.0122"
thick. Install above the cooktop with a clearance
of not less than
/
" between the hood and the
1
4
underside of the combustible material or metal
cabinet. The hood must be at least as wide as
the appliance and centered over the appliance.
Clearance between the cooking surface and the
ventilation hood surface must never be less than
24 inches.
Exception 1 : Installation of a listed microwave
oven or cooking appliance over the cooktop
shall conform to the installations packed with
that appliance.
• 30-in (76.2-cm) minimum clearance between
the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet; or
Installation guide
Hatched Faces should
be flat and leveled.
29
15
/
"
16
A: Cabinet opening 30" (76.2)
IMPORTANT: If your cabinet have height over 36 4/5", this range cannot be installed wirhout
supporting unit like hard block.
20 English
SLIDE-IN CUTOUT
3"
24"
3"
35-
/
"
7
8
23
3
/
16
36
3
/
"
16
A
26
/
"
7
16
If no 30-in (76.2-
24-in (61-cm) minimum when the bottom of
the wood or metal cabinet is protected by not
less than 0.25-in (0.64-cm) flame-retardant
millboard covered with not less than no. 28
MSG sheet steel, 0.015-in (0.038-cm) stainless
steel, 0.024-in (0.061-cm) aluminum, or
0.020-in (0.051-cm) copper.
• 18-in (45.7-cm) minimum between the
countertop and the adjacent cabinet bottom.
Exception 2 : For island installation, maintain
2-
/
" minimum from cutout to back edge of
1
2
countertop and 4" minimum from cutout to side
edges of countertop.
IMPORTANT:
To eliminate the risk of burns or fire caused
by reaching over heated surface units, avoid
having cabinet storage space located above the
surface units. If you have cabinet storage space
over the heating elements, you can reduce the
risk by installing a range hood that projects
horizontally a minimum of 5 inches beyond the
bottom of the cabinets.
1"min
/
"min.
1
2
"
25"
cm) minimum clearance,
 
FREESTANDING CUTOUT
3"
25"
24"
3"
A