Checking The Installation Site; Clearances And Dimensions; Minimum Dimensions - Samsung NE59R6631SG/AC Installation Manual

Table of Contents

Advertisement

Available languages

Available languages

CHECKING THE INSTALLATION SITE

Clearances and dimensions

To install the range, refer to the following figure.
For installation in CANADA, a Free-standing range is not to be installed closer than 12mm
from any adjacent surface.
CAUTION
CAUTION
cabinet temperatures of 194°F. Make sure the wall covering, countertops and cabinets around the
range can withstand the heat (up to 194°F) generated by the range. If not, discoloration, delamination
or melting may occur.
1
9
/
"
16
36" ~ 37"
29
15

Minimum dimensions

IMPORTANT
units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of
5" beyond the bottom of the cabinets.
** 15"
Manual Installation_30 Oven_SECA_DG68-00109F-08_EN+CFR.indb 4
This range has been designed to comply with the maximum allowable wood
25"
29
7
/
"
8
6"
28
7
/
"
16
24
7
/
"
8
26
1
/
"
16
46
1
/
" ~ 47
2
7
1
/
"
2
49
3
/
"
8
/
"
16
24
1
/
"
2
To eliminate the risk of burns or fire caused by reaching over heated surface
30"
* 30"
English - 4
3"
24"
3"
B
A
1
/
"
2
* 30" minimum clearance between the top
of the cooking surface and the bottom of
an unprotected wood or metal cabinet;
or 24" minimum when the bottom of the
wood or metal cabinet is protected by not
less than
/
" flame retardant millboard
1
4
covered with not less than no.28 MSG
sheet steel, 0.015" stainless steel, 0.024"
aluminum or 0.020" copper.
** 15" minimum between the countertop and
the adjacent cabinet bottom.
A : Cabinet opening
30" For U.S.A,
30"~31" For CANADA.
B : Acceptable
electrical outlet area
9/6/2018 6:52:50 PM