10-3. Test Operation

10-3-1. Gas Leak Test

Check the flare nut connections for gas leaks with a
gas leak detector and/or soapy water.
Fig. 10-3-1
10-3-2. Test Operation
To switch the TEST RUN (COOL) mode, press
RESET button for 10 sec.
(The beeper will make a short beep.)
RESET button
Fig. 10-3-2

10-3-3. Setting the Auto Restart

This product is designed so that, after a power
failure, it can restart automatically in the same
operating mode as before the power failure.
NOTE
The product was shipped with Auto Restart function
in the OFF position. Turn it ON as required.
1) Push and hold the RESET button for about
3 seconds. After 3 seconds, three short electric
beeps will be heard to inform you that the Auto
Restart has been selected.
2) To cancel the Auto Restart, follow the steps
described in the section Auto Restart Function of
the Owner's Manual.

10-3-4. Remote Control A-B Selection

• When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may
receive the remote control signal simultaneously and
operate. In this case, the operation can be preserved
by setting either one remote control to B setting.
(Both are set to A setting in factory shipment.)
• The remote control signal is not received when the
settings of indoor unit and remote control are different.
• There is no relation between A setting/B setting and A
room/B room when connecting the piping and cables.
<Remote control A-B selection>
To separate using of remote control for each indoor unit
in case of 2 air conditioners are installed nearly.
<Remote Control B Setup>
1. Press [RESET] button on the indoor unit to turn the air
conditioner ON.
2. . Point the remote control at the indoor uni
3.
Push and hold [CHECK] button on the Remote Control
by the tip of the pencil. "00" will be shown on the display
(Picture
)
1
4. Pres s [ MODE] during pushing [CHECK]. "B" will show
on the display and "00" will disappear and the air
conditioner will turn OFF. The Remote Control B
is memorized [Picture
NOTE : 1. Repeat above step to reset Remote
Control to be A.
2. . Remote Control A has not "A" displa
3. . Default setting of Remote Control fr
factory is A.
- 67 -
FILE NO. SVM-15036
).
2
1
Fig. 10-3-3
2