• Exposure of unit to water or other moisture before installation may result in an electrical short.
Do not store in a wet basement or expose to rain or water.
• Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify
the noise level of the unit or where noise or discharged air might disturb neighbors.
• To avoid personal injury, be careful when handling parts with sharp edges.
• Perform the specified installation work to guard against an earthquake.
If the air conditioner is not installed appropriately, accidents may occur due to the falling unit.
The indoor and outdoor units that can be used in combination are shown in the tables below.
Type
Outdoor unit
Heat pump
RAS-5M34S3AV-E, -A, -TR
NOTES
A 1-room connection is not an option for the indoor units (you cannot connect only one indoor unit).
Be sure to connect indoor units in two or more.

2-1. Specifications

<Heat Pump Models>
RAS-5M34S3AV-E, -A, -TR
Unit model
Outdoor
Cooling Capacity
Cooling Capacity range
Heating Capacity
Heating Capacity range
Power supply
Electric
characteristics
Total
COP
(Cooling/Heating)
Outdoor
Operating noise
(Cooling/Heating)
Dimension
Net weight
Outdoor unit
Compressor
Fan motor output
Air flow rate
Type
Outdoor unit
Piping connection
Maximum length (per unit)
Maximum length (total)
Maximum chargeless length
Maximum height difference
Name of refirigerant
Weight
Wiring connection
Power supply / interconnection
Usable temperature range
Outdoor
Unit model
Outdoor unit
Accessory
Installation manual
• For performance when each indoor unit is combined with other unit, refer to the separate table.
• The specifications may be subject to change without notice for purpose of improvement.
2. SPECIFICATIONS
Table of models that can be used in combination
Combinations of indoor unit models that can be connected
Refer to page 8 to 25
Operation mode
Running current
Power consumption
Power factor
Starting current
Full indoor units operating
Height
Width
Depth
Motor output
Type
Model
(m³/h)
A unit liquid side/gas side
B unit liquid side/gas side
C unit liquid side/gas side
D unit liquid side/gas side
E unit liquid side/gas side
(Cooling/Heating)
CAUTION
RAS-
RAS-
(kW)
(kW)
(kW)
(kW)
220-240V 1Ph 50Hz / 220V 1Ph 60Hz
Cooling
(A)
14.26 / 13.65 / 13.07
(W)
2980
(%)
95
(A)
(mm)
(mm)
(mm)
(kg)
(W)
Twin rotary type with DC-inverter variable speed control
(W)
(m)
(m)
(m)
(m)
(kg)
3 Wires : includes earth / 4 Wires : includes earth
(°C)
RAS-
- 5 -
FILE NO. SVM-15036
B13N3KV2-E1 (X5)
5M34S3AV-E, -A, -TR
10.0
3.7 to 11.0
12.0
2.7 to 14.0
Heating
13.56 / 12.97 / 12.43
2833
95
14.26 / 13.65 / 13.07
3.36 / 4.24
52 / 55
890
900
320
78
2200
DA270A2T-20LD
100
High: 3666, Medium: 2800
Flare connection
Ø6.35 / Ø12.7
Ø6.35 / Ø12.7
Ø6.35 / Ø9.52
Ø6.35 / Ø9.52
Ø6.35 / Ø9.52
25
80
40
15
R410A
2.99
-10 to 46 / -15 to 24
5M34S3AV-E, -A, -TR
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-5m34s3av-trRas-5m34s3av-a