Servicing The Fuses - Toro 74280TE Operator's Manual

Z597-d z master with a 62in or 72in turbo force side discharge mower
Table of Contents

Advertisement

2. Stop the engine, remove the key, and wait for
all moving parts to stop before leaving the
operating position.
3. Unlatch the seat and tilt the seat up.
4. First disconnect the negative battery cable from
the negative (-) battery terminal (Figure 45).
5. Slide the red terminal boot off the positive
(red) battery terminal. Then remove the
positive (red) battery cable (Figure 45).
Figure 45
1. Battery
2. J-bolts
3. Terminal boot
4. Wing nut (1/4 inch)
6. Remove the battery.
Installing the Battery
1. Position battery in the tray with the terminal
posts opposite from the hydraulic tank
(Figure 45).
2. First, install the positive (red) battery cable to
positive (+) battery terminal.
3. Then install the negative battery cable and
ground wire to the negative (-) battery terminal.
4. Secure the cables with 2 bolts (1/4 x 3/4 inch),
2 washers (1/4 inch), and 2 locknuts (1/4 inch)
(Figure 45).
5. Slide the red terminal boot onto the positive
(red) battery post.
6. Secure the battery with J-bolts, hold down
clamp, 2 washers (1/4 inch), and 2 wing nuts
(1/4 inch) (Figure 45).
5. Battery clamp
6. Ground wire
7. Red (+) cable
8. Black (-) cable
Charging the Battery
Charging the battery produces gasses that
can explode.
Never smoke near the battery and keep
sparks and flames away from battery.
Important: Always keep the battery
fully charged (1.265 specific gravity). This
is especially important to prevent battery
damage when the temperature is below 32°F
(0°C).
1. Make sure the filler caps are installed in battery.
Charge battery for 10 to 15 minutes at 25 to 30
amps or 30 minutes at 10 amps.
2. When the battery is fully charged, unplug
the charger from the electrical outlet, then
disconnect the charger leads from the battery
posts (Figure 46).
3. Install the battery in the machine and connect
the battery cables, refer to Installing the
Battery.
Note: Do not run the machine with the
battery disconnected, electrical damage may
occur.
Figure 46
1. Positive Battery Post
2. Negative Battery Post

Servicing the Fuses

The electrical system is protected by fuses. It
requires no maintenance, however, if a fuse blows
check component/circuit for malfunction or short.
41
3. Red (+) Charger Lead
4. Black (-) Charger Lead

Advertisement

Table of Contents
loading

This manual is also suitable for:

74281te

Table of Contents