Application 1: Basic Small Network Connection - Omega Engineering LDN-PS User Manual

Omega power supply user's guide
Table of Contents

Advertisement

7.0:
Applications (continued)

Application 1: Basic Small Network Connection.

Power supplied to network from PC via network card, no PSIM used.
Modules connected using standard communication cables.
Volt drop total in mV
Then approximate voltage at end of network
LDN-PS
=
cable 1 + module (3 off) + cable 2 + module (3 off)
=
(15.2 x 6) + 0.04(6+5+4+3+2+1) + (15.2 x 3) + 0.04(3+2+1)
=
138 mV
=
nominal supply voltage - calculated volt drop
=
5.1 - 0.138
=
4.96 V
19
PSIM-AC
PSIM-DC
PSIM-5V
M-3340/1206