6.0:
Specification (continued)

PSIM-5V

Line Voltage
see note 1
Input Current
Connection
see note 3
Isolation
Protection
see note 2
Note 1: No isolation or regulation is provided by the PSIM-5V. The voltage required should be set as required
to ensure correct operating voltage for each PIE that follows the PSIM-5V. See application notes for
further information.
Note 2: If there is a fault condition caused, for example, by a short circuit or transient, the protection circuits
will operate. The power must be removed and the fault corrected before the power is reinstated.
Under a fault condition, Orbit modules will not function correctly and a power on reset is required.
See application notes for further information.
Note 3: Supplied with 5m input cable as standard. This may be cut to length as required.
LDN-PS
5.1 Vdc Nominal as supplied by user
5.25 Vdc MAX
1.8 A MAX
5m flying lead (Red = positive, White = negative)
None
Current limiting resettable fuse
Over voltage 112% to 132% of nominal
Reverse connection
Transient
15
PSIM-AC
PSIM-DC
PSIM-5V
M-3340/1206