6.0:
Specification (continued)
All specifications are for a PSIM supplying a full network of probes.

PSIM-DC

Input
Line Voltage
Current
Connection
see note 3
Isolation
Protection
DC Output
Output Voltage
Output Current
Output Regulation
Transient Response
Ripple and Noise
Efficiency
Protection
see note 2
Thermal Derating
LDN-PS
10 to 30 Vdc.
1.1 A @ 12 Vdc; 0.5 A @ 24 Vdc (nominal).
5m flying lead (Red = positive, White = negative)
>500 VDC input/output
Input fuse and filter (not user replaceable)
Over voltage and under voltage shut down
Reverse connection
5.1 Vdc. Nominal
1.8 A max. (i.e. 31 Orbit Modules)
3% (Line / Load)
200us to 1% (FL to 1/2L)
< 1% p-p
80% to 86% typical
The output current shall be derated from 40 °C
to 60 °C by 50%. (ie. Max. output at 60 °C
is 0.9A or 15 Orbit Modules.)
14
PSIM-AC
PSIM-DC
PSIM-5V
M-3340/1206