Connection To Waterworks; Commissioning And Testing; Maintenance Of The Appliance; Possible Failures And Their Elimination - Tecnoinox BS80FE7 Instruction Manual For Installation And Use

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
-
Water inlet pressure must be between 50 and 300 kPa, otherwise install a pressure regulator on the line before the appliance.
-
Install a cut-off valve for each supply on the line before the appliance.
-
Make connections according to regulations currently in force.
Once all the connections have been made, the appliance and the overall installation must be checked following the directions given in this
-
manual.
Check in particular:
-
that the protective film has been removed from the external surfaces;
-
that the terminal board housing, removed for electrical connections, has been reinstalled.
-
that connections have been made in accordance with the requirements and directions indicated in this manual;
-
that all safety requirements in current standards, statutory regulations and directives have been met;
-
that the water connections are leak-free;
-
that the electrical connection has been performed according to standards.
-
In addition, check that once the appliance has been installed, the power cord is neither subject to stretch nor in contact with nor surfaces.
-
Now proceed to light the appliance as directed in the instructions for use.
-
While the appliance is in use, voltage should not differ from the nominal voltage more than +/- 10%.
-
The test report must be completed in full and submitted to the customer who should then sign in acceptance. With effect from this moment, the
-
appliance is covered by the manufacturer's warranty.
All maintenance operations shall only be performed by a technically qualified service centre!
-
-
To ensure correct and safe operation, the appliance must be inspected and serviced at least once a year only. Maintenance includes also to
control the components and tear of pipes, feeding pipes, electrical components etc..
-
It is advisable to replace worn components during maintenance operations to avoid the need for other maintenance calls and unexpected
failures.
-
It is also advisable to apply for a maintenance contract with the customer.
Only technically qualified service centres can perform the operations described below!
-
Before resetting the safety thermostat, it is always necessary to eliminate the problem causing its activation!
-
Even a normal use of the appliance may cause operation inconveniences and failures.
-
THE MOST COMMON PROBLEMS ARE THE FOLLOWING:
P
AN DOES NOT REACH SET TEMPERATURE
Possible causes:
- Check connections to the switch.
- Check connection to the working thermostat.
- Check connection to electromagnetic switch.
- Heating elements are burned.
S
IGNAL LAMPS DO NOT LIGHT UP
- Check the connection to the switch.
- Signal lamp is faulty.
THE BRATT PAN WORKS WITH DISCONNECTED THEMOSTAT
- Electromagnetic switch contacts are cut off.
L
OW EFFICIENTY OF THE PAN
- Check the heating elements.
BS80FE7 / BS80IE7

CONNECTION TO WATERWORKS

COMMISSIONING AND TESTING

MAINTENANCE OF THE APPLIANCE

POSSIBLE FAILURES AND THEIR ELIMINATION

:
24
Pag.