Step 5. Plug In And Place - Samsung NX58K3310S series Installation Manual

Hide thumbs Also See for NX58K3310S series:
Table of Contents

Advertisement

Available languages

Available languages

Step 5. Plug in and place

WARNING
BEFORE OPERATING OR TESTING, follow the grounding requirements on pages 14-
15 in this manual. Improper connection of the grounding plug can result in a risk
of electric shock.
• All gas ranges come with a power cord. The power cord is connected to the rear
of the range. Please review "Electrical requirements" on pages 14-15.
• All U.S. and Canadian models are produced with a 3-wire, 120-volt, 60-Hertz
electrical system. The entire system, including the power cord, is preinstalled and
prewired
Gas Range Plug
NX58K3310SS_AA_AC_DG68-00783A-00_EN.indd 19
1. Plug in the power cord. Make sure the
outlet meets local or national electrical
codes as referenced on pages 14-15.
2. Slide the range into place.
3. Check the gas supply line to make sure
it did not get damaged and it stayed
connected during positioning.
4. Check to make sure the back leg of the
range has slid into the anti-tip bracket.
Carefully tip the range forward to ensure
that the anti-tip bracket engages the back
brace and prevents tip-over.
Step 6. Level the range
1. Make sure the range is positioned where
2. Using a wrench, level the range by
Leveling leg
Adjusting the two front legs is usually
sufficient, but all four legs adjust if
necessary.
Adjust the leveling legs only as far as
necessary to level the range. Extending
the leveling legs more than necessary or
removing legs can cause the range to be
unstable.
3. If range is next to or between cabinets,
4. Position an oven rack in the center rack
5. Check the level of the range with a
6. After the range becomes level, slide the
you want it.
turning the front leveling legs in or out
as necessary. Counterclockwise shortens
the leg and lowers the range. Clockwise
lengthens the leg and raises the range.
NOTE
NOTE
make sure the cooktop (without the
surface burner grates) is level with the
countertops.
position.
carpenter level using the two positions
shown at right.
range away from the wall so that the
anti-tip bracket can be installed.
English 19
2015-12-02
7:26:04

Advertisement

Table of Contents
loading

Table of Contents