STEP 2C – PERMANENT HARD WIRING
It is possible to hard wire the DC charging leads to the battery for permanent
installations.
You will need 2 x ring terminals, an inline fuse holder and a fuse with the following
ratings. (See below)
PC400 = 7.5 Amp fuse
PC800 = 10 Amp fuse
PC1600 = 30 Amp fuse
PC2100 = 30 Amp fuse
Connection:
1. Cut off the supplied battery clips; ensure you leave sufficient cable to reach the
battery terminals. (DO NOT extend the battery charger DC leads, as the added
voltage drop will cause incorrect charging).
2. Fit a ring terminal to the BLACK Negative (-) wire.
3. Connect an inline fuse to the RED Positive (+) wire.
4. Connect a ring terminal to the other end of the inline fuse.
5. Connect the RED lead (with inline fuse and ring terminal) to the Positive (+)
battery post.
6. Connect the BLACK lead (with ring terminal) to the Negative (-) battery post.
7. Fit the correctly rated fuse.
If the charger is used in a Permanent/Hard Wired application and the vehicle will not
be used for some time, it is best to leave the charger connected to mains power (turned
'On') so that it can maintain the battery fully charged.
Ensure any modification to the 240V mains lead is carried out by a qualified person and
that connection to supply mains is in accordance with National wiring rules.