STEP 7 – DISCONNECTION
Ensure the 240V mains switch is turned off and the charger is disconnected from the
240V mains power.
Battery out of vehicle
Remove the BLACK lead (battery clip) from the battery.
Remove the RED lead (battery clip) from battery.
Battery in vehicle
Remove the chassis connection.
Remove the battery terminal connection.
STEP 8 – CHECK THE ELECTROLYTE LEVEL (CALCIUM MODE ONLY)
Check the electrolyte level and top up if required.

INITIATING REJUVENATION MODE

The rejuvenation mode can restore batteries from a deeply discharged state by breaking
down sulphation and revitalising the battery cells. A rejuvenation charge should be
performed periodically to optimise the battery's health and performance.
STEP 1
Follow STEPS 1 to 6 of the "Charging Instructions" of this booklet.
STEP 2 – HOLD DOWN THE BATTERY TYPE BUTTON
Hold the BATTERY TYPE button down for approx. 3 seconds until the REJUVENTATION
(REJ) LED begins flashing.
The charger will be in this mode for 24 hours, but can be manually stopped by holding
the BATTERY TYPE button down for approx. 3 seconds until the REJUVENTATION (REJ)
LED turns off.
Upon completion of the recondition, the charger will proceed to carry out a normal
charge on the battery.
STEP 3
Follow STEPS 7 to 9 of the Charging Instructions of this booklet.