STEP 3 – CONNECT TO 240V MAINS POWER
Connect the battery charger to the 240V mains powered socket and turn on the mains
power.
STEP 4 – SET CHARGE RATE
The charge rate should be set according to the size of the battery. To set, press the
CHARGE RATE button repeatedly until desired setting is displayed.
See the recommended charge rates for various battery sizes in the table below.
(Not all outputs are available on all models)
ADJUSTABLE CHARGE RATES:
CHARGE RATE
1 Amp
2 Amp
4 Amp
6 Amp
8 Amp
12 Amp
16 Amp
21 Amp
STEP 5 – SET BATTERY TYPE
The battery type should be set according to the type of battery being charged:
Normal (NORM) setting: suits GEL, AGM, WET batteries
Calcium (CAL) setting: suits CALCIUM batteries
To set, press the BATTERY TYPE button repeatedly until desired setting is displayed.
STEP 6 – CHARGING
During normal charging the LED panel will illuminate various signals, indicating the
different stages of charging.
When the battery is fully charged, the green FLOAT LED will illuminate. This indicates
the charger is in the float stage and the charger can be left connected to the battery
without over charging.
If the red FAULT LED illuminates, there is a fault; refer to the "Fault & Errors"
explanation on page 12 of this manual.
10
Deep Cycle (AH)
Automotive (CCA)
7-20
14-40
30-80
40-120
60-160
80-240
110-320
150-420
BATTERY SIZE (12V)
Marine (MCA)
40-120
55-170
80-240
110-330
180-480
250-650
240-720
330-1000
360-1000
500-1300
480-1440
660-2000
660-1900
930-2700
900-2500
1200-3500
Time (Hrs)
7-24
7-24
7-24
7-24
7-24
7-24
7-24
7-24

Hide quick links: